Evidence map›Paper›PMID 39691451›Full record

ArticleFoot & ankle orthopaedics2024

Impact of Joint Line Level in Total Ankle Arthroplasty: Standard Techniques vs Patient-Specific Instruments.

Alberto Arceri, Antonio Mazzotti, Federico Sgubbi, Simone O Zielli, Elena Artioli, Laura Langone, Pejman Abdi, Cesare Faldini

Abstract read
In one paragraph

Article in Foot & ankle orthopaedics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Alberto Arceri1st Orthopaedics and Traumatologic Clinic, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy.ORCID https://orcid.org/0000-0002-6486-6300
Antonio Mazzotti1st Orthopaedics and Traumatologic Clinic, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy.ORCID https://orcid.org/0000-0001-9974-4787
Federico Sgubbi1st Orthopaedics and Traumatologic Clinic, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy.ORCID https://orcid.org/0009-0006-6700-207X
Simone O Zielli1st Orthopaedics and Traumatologic Clinic, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy.
Elena Artioli1st Orthopaedics and Traumatologic Clinic, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy.ORCID https://orcid.org/0000-0001-9279-4722
Laura Langone1st Orthopaedics and Traumatologic Clinic, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy.
Pejman Abdi1st Orthopaedics and Traumatologic Clinic, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy.
Cesare Faldini1st Orthopaedics and Traumatologic Clinic, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Total ankle arthroplasty (TAA) is an effective treatment for severe end-stage ankle osteoarthritis (AO). Despite satisfactory results, range of motion (ROM) is still suboptimal compared to healthy ankles. This issue may stem from different conditions, and the difficulty in accurately restoring the height of the joint line may be one of them. Recent studies in TAA have demonstrated that an elevated joint line is associated with reduced postoperative ROM and poorer functional scores. To improve the accuracy of bone resection and implant positioning, the use of patient-specific instruments (PSIs) has been proposed. The aim of this study is to compare joint line height, ROM, and functional clinical outcomes between standard TAA and TAA using PSI. Methods: A retrospective analysis was conducted on a consecutive cohort of patients who underwent standard TAA and TAA with PSI between January 2020 and December 2022. Radiographic assessments, including measurement of joint line height ratio (JLHR) and ROM, were performed. The clinical outcome was assessed using the Forgotten Joint Score. Result: Fifty-one patients underwent standard TAA, whereas 13 received TAA with PSI. The mean JLHR preoperatively was 1.51 ± 0.24 and postoperatively was 1.56 ± 0.23 in the standard TAA group ( Conclusion: This study suggests that PSI may improve the accuracy of reestablishing this implant's alignment closer to the native joint line. However, contrary to the study's initial hypothesis, PSI was not associated with any difference in ROM or clinical outcomes compared with standard TAA technique. Additional factors including the prosthetic implant design, presence of heterotopic calcifications, soft tissue contracture, surgical technique, post-TAA tibial slope, and preoperative ROM may have a greater impact than joint line level. Level of Evidence: Level III, retrospective cohort study.

Indexed as

joint linepatient-specific instrumentsrange of motiontotal ankle arthroplasty

Identifiers

PMID39691451
PMCPMC11650474

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.