Evidence map›Paper›PMID 39687530›Full record

ArticleEuropean heart journal. Case reports2024

Integration of a surgical bipolar ablation device within an electroanatomical mapping system during epicardial ventricular tachycardia ablation via video-assisted thoracoscopic surgery: a case report.

Mark T Mills, Kirstin Welsh, Jonathan Sahu, Steven Hunter, Graeme J Kirkwood

Erratum issuedAbstract readCase Reports
In one paragraph

Article in European heart journal. Case reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors.

Mark T MillsLiverpool Centre for Cardiovascular Science at University of Liverpool, Liverpool John Moores University and Liverpool Heart & Chest Hospital, William Henry Duncan Building, 6 W Derby St, Liverpool L7 8TX, UK.ORCID https://orcid.org/0000-0002-5425-7739
Kirstin WelshLiverpool Centre for Cardiovascular Science at University of Liverpool, Liverpool John Moores University and Liverpool Heart & Chest Hospital, William Henry Duncan Building, 6 W Derby St, Liverpool L7 8TX, UK.
Jonathan SahuLiverpool Centre for Cardiovascular Science at University of Liverpool, Liverpool John Moores University and Liverpool Heart & Chest Hospital, William Henry Duncan Building, 6 W Derby St, Liverpool L7 8TX, UK.ORCID https://orcid.org/0009-0002-1180-5253
Steven HunterDepartment of Cardiothoracic surgery, The Northern General Hospital, Sheffield Teaching Hospitals NHS Foundation Trust, Herries Road, Sheffield S5 7AU, UK.
Graeme J KirkwoodLiverpool Centre for Cardiovascular Science at University of Liverpool, Liverpool John Moores University and Liverpool Heart & Chest Hospital, William Henry Duncan Building, 6 W Derby St, Liverpool L7 8TX, UK.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Epicardial ventricular tachycardia (VT) ablation is an established approach in patients with epicardial arrhythmogenic foci and is most commonly performed via percutaneous access. An alternative approach is via video-assisted thoracoscopic surgery (VATS), although reports of this technique are limited to the use of catheter-based technologies for radiofrequency ablation delivery. Case summary: A 55-year-old man with non-ischaemic cardiomyopathy presented with recurrent VT despite medical therapy. Twelve-lead ECG and cardiac MRI were suggestive of an epicardial left ventricular lateral wall breakout. Epicardial ablation was successfully performed via VATS using a linear surgical bipolar ablation device with electroanatomical mapping (EAM) integration. Following ablation, VT was non-inducible. Other than six short episodes of non-sustained during initial follow-up (up to 6 weeks), the patient remained free of ventricular arrhythmias at 18 months with minimal anti-arrhythmic therapy. Discussion: Epicardial VT ablation via VATS is feasible and allows for integration of a surgical ablation device within an EAM system. This may serve as an alternative approach in patients with a failed percutaneous ablation, or those with adverse features for a successful percutaneous procedure.

Indexed as

Case reportCatheter ablationElectroanatomical mappingSurgical ablationVentricular tachycardia

Identifiers

PMID39687530
PMCPMC11647582

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked