ArticleSensors (Basel, Switzerland)2024
Hardware Implementation for Triaxial Contact-Force Estimation from Stress Tactile Sensor Arrays: An Efficient Design Approach.
Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
This paper presents a contribution to the state of the art in the design of tactile sensing algorithms that take advantage of the characteristics of generalized sparse matrix-vector multiplication to reduce the area, power consumption, and data storage required for real-time hardware implementation. This work also addresses the challenge of implementing the hardware to execute multiaxial contact-force estimation algorithms from a normal stress tactile sensor array on a field-programmable gate-array development platform, employing a high-level description approach. This paper describes the hardware implementation of the proposed sparse algorithm and that of an algorithm previously reported in the literature, comparing the results of both hardware implementations with the software results already validated. The calculation of force vectors on the proposed hardware required an average time of 58.68 ms, with an estimation error of 12.6% for normal forces and 7.7% for tangential forces on a 10 × 10 taxel tactile sensor array. Some advantages of the developed hardware are that it does not require additional memory elements, achieves a 4× reduction in processing elements compared to a non-sparse implementation, and meets the requirements of being generalizable, scalable, and efficient, allowing an expansion of the applications of normal stress sensors in low-power tactile systems.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.