Evidence map›Paper›PMID 39686319›Full record

ArticleSensors (Basel, Switzerland)2024

Real-Time Postural Disturbance Detection Through Sensor Fusion of EEG and Motion Data Using Machine Learning.

Zhuo Wang, Avia Noah, Valentina Graci, Emily A Keshner, Madeline Griffith, Thomas Seacrist, John Burns, Ohad Gal, Allon Guez

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Zhuo WangDepartment of Electrical and Computer Engineering, Drexel University, Philadelphia, PA 19104, USA.ORCID 0000-0003-0598-0573
Avia NoahGraceFall, Inc., Penn Valley, PA 19702, USA.ORCID 0000-0001-6498-2910
Valentina GraciCenter for Injury Research and Prevention, Children's Hospital of Philadelphia, Philadelphia, PA 19104, USA.ORCID 0000-0002-8006-0067
Emily A KeshnerGraceFall, Inc., Penn Valley, PA 19702, USA.
Madeline GriffithCenter for Injury Research and Prevention, Children's Hospital of Philadelphia, Philadelphia, PA 19104, USA.
Thomas SeacristCenter for Injury Research and Prevention, Children's Hospital of Philadelphia, Philadelphia, PA 19104, USA.
John BurnsCenter for Injury Research and Prevention, Children's Hospital of Philadelphia, Philadelphia, PA 19104, USA.
Ohad GalGraceFall, Inc., Penn Valley, PA 19702, USA.
Allon GuezDepartment of Electrical and Computer Engineering, Drexel University, Philadelphia, PA 19104, USA.

Funding

Sensor Fusion System For Early And Accurate Fall Detection and Injury ProtectionR43AG067843 · NIA · GRACEFALL, INC. · PI KESHNER, EMILY A · 2021 to 2021
$299k
National Institutes of Health, National Institute on Aging 1R43AG067843
6 · The paper itself

Abstract

Millions of people around the globe are impacted by falls annually, making it a significant public health concern. Falls are particularly challenging to detect in real time, as they often occur suddenly and with little warning, highlighting the need for innovative detection methods. This study aimed to assist in the advancement of an accurate and efficient fall detection system using electroencephalogram (EEG) data to recognize the reaction to a postural disturbance. We employed a state-space-based system identification approach to extract features from EEG signals indicative of reactions to postural perturbations and compared its performance with those of traditional autoregressive (AR) and Shannon entropy (SE) methods. Using EEG epochs starting from 80 ms after the onset of the event yielded improved performance compared with epochs that started from the onset. The classifier trained on the EEG data achieved promising results, with a sensitivity of up to 90.9%, a specificity of up to 97.3%, and an accuracy of up to 95.2%. Additionally, a real-time algorithm was developed to integrate the EEG and accelerometer data, which enabled accurate fall detection in under 400 ms and achieved an over 99% accuracy in detecting unexpected falls. This research highlights the potential of using EEG data in conjunction with other sensors for developing more accurate and efficient fall detection systems, which can improve the safety and quality of life for elderly adults and other vulnerable individuals.

Indexed as

Accidental FallsAlgorithmsElectroencephalographyMachine LearningAdultFemaleHumansMalePostural BalancePostureSignal Processing, Computer-AssistedEEGelderly adultsfall detectionsensor fusionsystem identification

Identifiers

PMID39686319
PMCPMC11645098

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.