Evidence map›Paper›PMID 39686262›Full record

ArticleSensors (Basel, Switzerland)2024

Preliminary Characterization of a Novel Aerosol Jet-Printed Strain Sensor for Feasibility Assessment in a Variable Stiffness Arterial Simulator Application.

Federico Filippi, Giorgia Fiori, Annalisa Genovesi, Massimiliano Barletta, Matteo Lancini, Mauro Serpelloni, Andrea Scorza, Salvatore Andrea Sciuto

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Federico FilippiDepartment of Industrial, Electronic and Mechanical Engineering, University of Roma Tre, 00146 Rome, Italy.ORCID 0000-0003-0102-7726
Giorgia FioriDepartment of Industrial, Electronic and Mechanical Engineering, University of Roma Tre, 00146 Rome, Italy.ORCID 0000-0001-7143-5499
Annalisa GenovesiDepartment of Industrial, Electronic and Mechanical Engineering, University of Roma Tre, 00146 Rome, Italy.ORCID 0000-0001-8077-1304
Massimiliano BarlettaDepartment of Industrial, Electronic and Mechanical Engineering, University of Roma Tre, 00146 Rome, Italy.ORCID 0000-0002-1277-8034
Matteo LanciniDepartment of Medical and Surgical Specialties, Radiological Sciences, and Public Health, University of Brescia, 25121 Brescia, Italy.ORCID 0000-0002-2301-876X
Mauro SerpelloniDepartment of Information Engineering, University of Brescia, 25123 Brescia, Italy.ORCID 0000-0001-6497-5876
Andrea ScorzaDepartment of Industrial, Electronic and Mechanical Engineering, University of Roma Tre, 00146 Rome, Italy.ORCID 0000-0002-3542-8854
Salvatore Andrea SciutoDepartment of Industrial, Electronic and Mechanical Engineering, University of Roma Tre, 00146 Rome, Italy.ORCID 0000-0001-7072-1055

Funding

Project ECS 0000024 Rome Technopole - CUP [F83B22000040006], NRP Mission 4 Component 2 Investment 1.5, Funded by the European Union - NextGenerationEU". F83B22000040006
6 · The paper itself

Abstract

Wearable strain sensors are widespread in many fields, including the biomedical field where they are used for their stretchability and ability to be applied to non-regular surfaces. The study of the propagation speed of the pressure wave generated by the heartbeat within vessels, i.e., the Pulse Wave Velocity (PWV), is of significant relevance in this field to assess arterial stiffness, a parameter commonly used for the early diagnosis of cardiovascular diseases. In this context, arterial simulators are useful tools to study the relationship between the PWV and other hemodynamic quantities in vitro. This study aims to characterize novel strain sensors to assess their suitability within an arterial simulator capable of varying the stiffness of an arterial surrogate by varying the transmural pressure. Six sensors deposited on arterial surrogates by Aerosol Jet Printing technology were subjected to deformation through a load frame. The results show that the sensors were able to distinguish strains of 0.1%, the maximum strain was around 6-8%, and the fatigue strength depended strongly on the strain rate.

Indexed as

Vascular StiffnessAerosolsArteriesFeasibility StudiesHumansPulse Wave AnalysisWearable Electronic DevicesAerosolsaerosol jet printingarterial simulatorcharacterizationdynamic teststrain measurementsstrain sensors

Identifiers

PMID39686262
PMCPMC11645093

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.