Evidence map›Paper›PMID 39686165›Full record

ArticleSensors (Basel, Switzerland)2024

Improving Electrical Stimulation Effectiveness and Versatility for Non-Invasive Transdermal Monitoring Applications via an Innovative Mixed-Signal Electronic Interface.

Alessandro Zompanti, Davide Ciarrocchi, Simone Grasso, Riccardo Olivieri, Giuseppe Ferri, Marco Santonico, Giorgio Pennazza

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Alessandro ZompantiResearch Unit of Electronics for Sensor Systems, Department of Engineering, University Campus Bio-Medico di Roma, 00128 Rome, Italy.ORCID 0000-0001-5986-4426
Davide CiarrocchiResearch Unit of Electronics for Sensor Systems, Department of Engineering, University Campus Bio-Medico di Roma, 00128 Rome, Italy.ORCID 0000-0002-8521-7692
Simone GrassoResearch Unit of Electronics for Sensor Systems, Department of Science and Technology for Sustainable Development and One Health, University Campus Bio-Medico di Roma, 00128 Rome, Italy.ORCID 0000-0003-0507-7966
Riccardo OlivieriDepartment of Industrial and Information Engineering and Economics (DIIIE), University of L'Aquila, 67100 L'Aquila, Italy.
Giuseppe FerriDepartment of Industrial and Information Engineering and Economics (DIIIE), University of L'Aquila, 67100 L'Aquila, Italy.ORCID 0000-0002-8060-9558
Marco SantonicoResearch Unit of Electronics for Sensor Systems, Department of Science and Technology for Sustainable Development and One Health, University Campus Bio-Medico di Roma, 00128 Rome, Italy.
Giorgio PennazzaResearch Unit of Electronics for Sensor Systems, Department of Engineering, University Campus Bio-Medico di Roma, 00128 Rome, Italy.ORCID 0000-0003-4843-9445

Funding

Project ECS 0000024 Rome Technopole - CUP C83C22000510001 Project ECS 0000024 Rome Technopole - CUP C83C22000510001
6 · The paper itself

Abstract

Electrical stimulation can be used in several applications such as fatigue reduction, muscle rehabilitation, neurorehabilitation, neuro-prosthesis and pain relief. Moreover, electrical stimulation can be used for drug delivery applications or body fluids extraction (e.g., sweat and interstitial fluid) to successively monitor several parameters, such as glucose, lactate, etc. All these applications are performed using electrical stimulator devices capable of applying constant voltage pulses or constant current pulses via electrodes to human tissues. Usually, constant current stimulators are most widely used because of their safety, stability, and repeatability. Thus, the aim of this work was to design, realize and test a mixed-signal electronic interface capable of producing current pulses with custom amplitude, duration, frequency, polarity and symmetry with extended voltage compliance. To achieve this result, we developed a high-voltage current stimulator suitable for iontophoresis applications. Current stimuli can be applied setting the intensity, frequency and duty cycle of the stimulation patterns through a µC. A custom electronic interface was designed to allow the control of the injected current in real time and to prevent electrical injuries to the patient by avoiding potential unwanted short circuits. Moreover, the system was tested in a simulated environment demonstrating its effectiveness and applicability for transdermal monitoring applications. The obtained results show that the device is able to apply monophasic and biphasic pulses, ranging from 0.1 to 10 mA, with a maximum error of about 10% at the minimum intensity; in addition, current stimuli can be applied up to a maximum frequency of 100 kHz with a voltage compliance of 120 V.

Indexed as

Electric StimulationElectrodesHumansIontophoresisMonitoring, PhysiologicSkincurrent stimulationdrug deliveryelectrical stimulationfunctional electrical stimulationmixed-signal interfacereverse iontophoresistransdermal monitoring

Identifiers

PMID39686165
PMCPMC11645059

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.