ArticleSensors (Basel, Switzerland)2024
Development of an Integrating Sphere-Based Wide-Range Light Source System for the Linearity Evaluation of a Photodetector Used in Radiation Detection and Bioanalysis Instruments.
Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
We developed a compact wide-range light source system for evaluating the linearity of photomultiplier tube (PMT) output. This system utilizes two integrating spheres equipped with a continuously variable slit and output aperture to modulate a stabilized light-emitting diode light source, producing an output light range as wide as seven orders of magnitude. To verify the wide linearity range of the integrating sphere system, three silicon photodiodes coupled with electric current readers monitored the light intensity and simultaneously confirmed each other's linearity. Using this system, we evaluated the linearity of the PMT used in a neutron detector we are currently developing and found it to have a linear range of more than four orders of magnitude. Non-linearity characteristics were also successfully measured in detail at a higher output range. Neutron detector operation requires both calibration of the detection efficiency and evaluation of the linearity between the neutron dose and its output. These results indicate that this system is a simple and useful method to evaluate the linearity of photodetectors used in radiation detectors and other applications.