ArticleSensors (Basel, Switzerland)2024
Evaluation of Different Commercial Sensors for the Development of Their Automatic Irrigation System.
Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Development and Performance Analysis of a U-Shaped Fiber Optic Sensor for Soil Water Content Measurement.Sensors (Basel, Switzerland) · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Reliable soil moisture information is essential for accurate irrigation scheduling. A wide range of soil moisture sensors are currently available on the market, but their performance needs to be evaluated as most sensors are calibrated under limited laboratory conditions. The aim of this study was to evaluate the performance of six commercially available moisture sensors (HydraProbe, Teros 10, Teros 11, EnviroPro, CS616 and Drill & Drop) and three tensiometers (Irrometer RSU-C-34, Teros 32 and Teros 21) and to establish calibration equations for a typical sandy soil of the Doñana National Park (Huelva, Spain). The calibration process for soil moisture sensors indicated differences between factory and corrected equations. All tested sensors improved with adjustments made to the factory calibration, except for the HydraProbe sensor which had a more accurate factory equation for a sandy soil. Among the various sensors tested, the Teros 10, Teros 11, and HydraProbe were found to be the easiest to install, typically positioned with an auger to prevent preferential pathways and ensure adequate sensor-soil contact. For tensiometers, the Teros 32 sensor requires specialized labor for its correct installation, as it must be positioned at a specific angle and maintained with distilled water. All tensiometers need a stabilization period after installation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.