Precise Mechanical Oscillator Design and Calibration for Characterising Sub-Millimetre Movements in mmWave Radar Systems.
Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
For many industrial and medical applications, measuring sub-millimetre movements has become crucial, for instance, for the precise guidance of surgical robots. The literature shows the feasibility of millimetre-wave (mmWave) radars to deal with such micro-vibrations. However, the availability of reference devices to configure and test these systems is very limited. This work proposes the design of a mechanical oscillator to characterise sub-millimetre vibration detection and measurement using a mmWave radar. The final implementation is fully controllable in both amplitude and frequency. Additionally, it can be wirelessly controlled and synchronised with other systems. Its functioning was experimentally calibrated and tested using the sub-millimetre motion capture system OptiTrack. It was tested to generate low-frequency oscillations from 0.80 Hz to 3.50 Hz with reliable peak amplitudes of 0.05 mm and above, with less than 6% peak amplitude relative error. Finally, the device was used to characterise a 60 GHz mmWave radar with those values.