Evidence map›Paper›PMID 39685958›Full record

ArticleSensors (Basel, Switzerland)2024

Comparison of Velocity and Estimated One Repetition Maximum Measured with Different Measuring Tools in Bench Presses and Squats.

Roland van den Tillaar, Hallvard Nygaard Falch, Stian Larsen

Abstract readComparative Study
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Roland van den TillaarDepartment of Sport Sciences and Physical Education, Nord University, 7600 Levanger, Norway.ORCID 0000-0002-4481-4490
Hallvard Nygaard FalchDepartment of Sport Sciences and Physical Education, Nord University, 7600 Levanger, Norway.
Stian LarsenDepartment of Sport Sciences and Physical Education, Nord University, 7600 Levanger, Norway.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The aim of this study was to compare barbell velocities at different intensities and estimated 1-RM with actual 1-RM measured with different measuring tools in bench presses and squats. Fourteen resistance-trained athletes (eight men, six women, age 28.1 ± 7.5 years, body mass 78.1 ± 12.2 kg, body height 1.73 ± 0.09 m) performed bench presses and squats at five loads varying from 45 to 85% of one repetition maximum (1-RM), together with 1-RM testing, while measuring mean, mean propulsive, and peak barbell velocity with six different commercially used inertial measurement units (IMUs) and linear encoder software systems attached to the barbell. The 1-RM was also estimated based upon the load-velocity regression, which was compared with the actual 1-RM in the bench press and squat exercises. The main findings were that GymAware revealed the highest reliability along with minimal bias, while Musclelab and Vmaxpro showed moderate reliability with some variability at higher loads. Speed4lifts and PUSH band indicated greater variability, specifically at higher intensities. Furthermore, in relation to the second aim of the study, significant discrepancies were found between actual and estimated 1-RM values, with Speed4lifts and Musclelab notably underestimating 1-RM. These findings underscore the importance of selecting reliable tools for accurate velocity-based training and load prescription.

Indexed as

Resistance TrainingWeight LiftingAdultAthletesBiomechanical PhenomenaFemaleHumansMaleMuscle StrengthYoung Adult1-RMmean propulsive velocitymean velocitypeak velocityresistance trainingstrength

Identifiers

PMID39685958
PMCPMC11644249

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.