Evidence map›Paper›PMID 39685145›Full record

ArticleMaterials (Basel, Switzerland)2024

Modification of Ti-Al-V Alloys with Layers Containing TiN Particles Obtained via the Electrophoretic Deposition Process: Surface and Structural Properties.

Maria Biegun-Żurowska, Anna Berezicka, Marcin Gajek, Tomasz Goryczka, Magdalena Ziąbka

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Maria Biegun-ŻurowskaDepartment of Ceramics and Refractories, Faculty of Materials Science and Ceramics, AGH University of Krakow, 30-059 Krakow, Poland.ORCID 0000-0003-1087-5129
Anna BerezickaDepartment of Ceramics and Refractories, Faculty of Materials Science and Ceramics, AGH University of Krakow, 30-059 Krakow, Poland.ORCID 0000-0002-1881-2643
Marcin GajekDepartment of Ceramics and Refractories, Faculty of Materials Science and Ceramics, AGH University of Krakow, 30-059 Krakow, Poland.ORCID 0000-0002-6020-8060
Tomasz GoryczkaInstitute of Materials Science, University of Silesia in Katowice, 75 Pułku Piechoty 1A, 41-500 Chorzow, Poland.ORCID 0000-0002-6405-2825
Magdalena ZiąbkaDepartment of Ceramics and Refractories, Faculty of Materials Science and Ceramics, AGH University of Krakow, 30-059 Krakow, Poland.ORCID 0000-0003-0702-7137

Funding

AGH University of Krakow "Excellence Initiative - Research University" 4089 and 1449
6 · The paper itself

Abstract

The aim of this work was to obtain homogenous coatings containing chitosan with different concentrations of titanium nitride particles (TiN). The coatings were deposited via an electrophoretic process on an etched medically pure Ti-6Al-4V alloy. As part of the study, the zeta potential of the suspensions used for EPD coating deposition was measured, allowing for the optimization of process parameters and the assessment of suspension stability. Subsequently, the research focused on evaluating the microstructure (SEM + EDS), structure (XRD), and surface characteristics (roughness, contact angle, surface energy, microhardness, coating adhesion) of the deposited layers. SEM microscopy confirmed the effective deposition of titanium nitride particles onto the titanium alloy surface. XRD analysis proved the assumed phase composition of the coating. The increase in TiN phase content in the individual layers was confirmed. The chitosan/TiN layer's introduction altered the alloy surface, increasing its roughness and static water contact angle. The highest roughness and hydrophobic properties were observed in the coating with a 2 wt.% concentration of titanium nitride particles. Additionally, the coating containing the highest concentration of ceramic particles (2 wt.%) exhibited the highest hardness (197 HV) among all the tested layers. However, the TiN particles incorporation in the layer decreased the adhesion strength, from 2.36 MPa (0.5 wt.% TiN) to 1.04 MPa (2 wt.% TiN). The coatings surface and structural properties demonstrate potential as protective layers for implants and are suitable for further biological studies to assess their applicability in medical and veterinary fields.

Indexed as

chitosan EPDelectrophoretic depositionsurface and structural propertiestitanium alloytitanium nitride particles

Identifiers

PMID39685145
PMCPMC11642151

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.