Evidence map›Paper›PMID 39685136›Full record

ArticleMaterials (Basel, Switzerland)2024

Shear Strengthening of RC Beams Using Prestressed Near-Surface Mounted Bars Reducing the Probability of Construction Failure Risk.

Sabry Fayed, Mohamed Ghalla, Jong Wan Hu, Ehab A Mlybari, Abdullah Albogami, Saad A Yehia

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Sabry FayedCivil Engineering Department, Faculty of Engineering, Kafrelsheikh University, Kafr El-Sheikh 33516, Egypt.
Mohamed GhallaCivil Engineering Department, Faculty of Engineering, Kafrelsheikh University, Kafr El-Sheikh 33516, Egypt.
Jong Wan HuDepartment of Civil and Environmental Engineering, Incheon National University, Incheon 22012, Republic of Korea.ORCID 0000-0001-6081-4469
Ehab A MlybariDepartment of Civil Engineering, College of Engineering and Architecture, Umm Al-Qura University, Makkah 24382, Saudi Arabia.
Abdullah AlbogamiDepartment of Civil Engineering, Faculty of Engineering, Al-Baha University, Al-Baha 65779, Saudi Arabia.ORCID 0009-0005-8540-7815
Saad A YehiaDepartment of Civil Engineering, Higher Institute of Engineering and Technology, Kafr El-Sheikh 35516, Egypt.ORCID 0009-0002-1331-7157

Funding

Incheon National University Research Grant in 2024
6 · The paper itself

Abstract

In this study, shear-critical reinforced concrete (RC) beams were strengthened by combining the prestressing and near-surface mounted (NSM) rods approaches. The potential danger of failure in such RC beams is a substantial concern as it is considered a potential threat. This study addresses its careful mitigation through experimental identification and numerical analysis to enhance the safety and sustainability of buildings by reducing the probability of failure risk for these RC beams. Nine of the ten RC beams that were tested had strengthened, and one had not. Internal prestressing (IP) within the beam body, external prestressing NSM (PNSM), internal embedment (IE) inside the beam with or without prestressing, and NSM are the strengthening technologies that were employed. The range of the extra shear reinforcement ratios (μs) was 0.87% to 1.60%. We investigated how strengthened beams behaved structurally in terms of the cracking load, ultimate load, load-deflection response, ultimate deflection, and stiffness. The insertion of five pairs of PNSM rods (μs = 1.45%) and five pairs of IP rods (μs = 1.6%), respectively, increased the beams' shear capacity by 57.8% and 70.4%. Shear capacity increased by 23.2% when three pairs of IE rods (μs = 1.02%) were installed. The prestressing location had an impact on shear capacity, with the interior case surpassing the external one. Compared to the control, the stiffness of the strengthened beams rose by 20%, 82%, and 84.4% when three, four, or five pairs of internal prestressing rods were added. A formula is proposed to calculate the shear capacity of all beams strengthened using various methods.

Indexed as

construction failuredrilled holesgroovesNSMprestressingRC beamsrisk mitigationshear strengtheningsustainability

Identifiers

PMID39685136
PMCPMC11642131

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.