ArticleMolecules (Basel, Switzerland)2024
Novel Spectrophotometric Method for Robust Detection of Trace Copper and Cobalt in High-Concentration Zinc Solution.
Article in Molecules (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Coupling Rare-Earth Complexes with Carbon Dots via Surface Imprinting: A New Strategy for Spectroscopic CuMolecules (Basel, Switzerland) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
In the purification process of zinc hydrometallurgy, the spectra of copper and cobalt seriously overlap in the whole band and are interfered with by the spectra of zinc and nickel, which seriously affects the detection results of copper and cobalt in zinc solutions. Aiming to address the problems of low resolution, serious overlap, and narrow characteristic wavelengths, a novel spectrophotometric method for the robust detection of trace copper and cobalt is proposed. First, the Haar, Db4, Coif3, and Sym3 wavelets are used to carry out the second-order continuous wavelet transform on the spectral signals of copper and cobalt, which improves the resolution of copper and cobalt and eliminates the background interference caused by matrix zinc signals and reagents. Then, the information ratio and separation degree are defined as optimization indexes, a multi-objective optimization model is established with the wavelet decomposition scale as a variable, and the non-inferior solution of multi-objective optimization is solved by the state transition algorithm. Finally, the optimal second-derivative spectra combined with the fine zero-crossing technique are used to establish calibration curves at zero-crossing points for the simultaneous detection of copper and cobalt. The experimental results show that the detection performance of the proposed method is far superior to the partial least squares and Kalman filtering methods. The RMSEPs of copper and cobalt are 0.098 and 0.063, the correlation coefficients are 0.9953 and 0.9971, and the average relative errors of copper and cobalt are 3.77% and 2.85%, making this method suitable for the simultaneous detection of trace copper and cobalt in high-concentration zinc solutions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.