ArticleNanomaterials (Basel, Switzerland)2024
Haptic-Based Real-Time Platform for Microswarm Steering in a Multi-Bifurcation Vascular Network.
Article in Nanomaterials (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
The use of electromagnetic fields to control a collection of magnetic nanoparticles, known as a microswarm, has many promising applications. Current research often makes use of accurate but time-consuming simulations lacking real-time human input. On the contrary, human interaction is possible with a real-time simulator, allowing the collection of valuable user interaction data. This paper presents the development and validation of a real-time two-dimensional microswarm simulator to accommodate the human interaction aspect. A haptic device is used to steer the microswarm through a multi-bifurcation vascular network towards a selected outlet. The percentage of particles reaching the selected outlet is used as the success metric. The simulator is verified against collected real-world experimental data and shows an 8% deviation. Parametric studies demonstrate the most influential parameters. We found that reducing the magnetic gradient from 1000 mT/m to 100 mT/m resulted in a decrease in recorded performance from 100% to 30.8%. Variation in fluid flow also had a considerable effect on the recorded performance, presenting a drop from 100% to 35.3% when fluid flow velocities increased from 0.005 m/s to 0.06 m/s. Changing the starting arrangement of particles resulted in a drop to 59% over the same range of fluid flow velocities.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.