Evidence map›Paper›PMID 39682364›Full record

ArticleAnimals : an open access journal from MDPI2024

Simultaneous, Non-Contact and Motion-Based Monitoring of Respiratory Rate in Sheep Under Experimental Condition Using Visible and Near-Infrared Videos.

Beatriz Leandro Bonafini, Lukas Breuer, Lisa Ernst, René Tolba, Lucas Ferrari de Oliveira, Mauren Abreu de Souza, Michael Czaplik, Carina Barbosa Pereira

Abstract read
In one paragraph

Article in Animals : an open access journal from MDPI, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Beatriz Leandro BonafiniPost Graduate Program in Technology in Health, Polytechnique School, Pontifical Catholic University of Paraná, Curitiba 80215-901, Brazil.ORCID 0000-0003-0885-2411
Lukas BreuerDepartment of Anesthesiology, Faculty of Medicine, RWTH Aachen University, 52074 Aachen, Germany.ORCID 0009-0001-1481-2398
Lisa ErnstInstitute for Laboratory Animal Science & Experimental Surgery, Faculty of Medicine, RWTH Aachen University, 52074 Aachen, Germany.ORCID 0000-0003-3808-4222
René TolbaInstitute for Laboratory Animal Science & Experimental Surgery, Faculty of Medicine, RWTH Aachen University, 52074 Aachen, Germany.
Lucas Ferrari de OliveiraDepartment of Informatics, Federal University of Paraná, Curitiba 81530-000, Brazil.ORCID 0000-0002-8198-0877
Mauren Abreu de SouzaPost Graduate Program in Technology in Health, Polytechnique School, Pontifical Catholic University of Paraná, Curitiba 80215-901, Brazil.ORCID 0000-0001-6137-918X
Michael CzaplikDepartment of Anesthesiology, Faculty of Medicine, RWTH Aachen University, 52074 Aachen, Germany.ORCID 0000-0002-7118-7728
Carina Barbosa PereiraDepartment of Anesthesiology, Faculty of Medicine, RWTH Aachen University, 52074 Aachen, Germany.ORCID 0000-0003-1788-4562

Funding

Coordination for the Improvement of Higher Education Personnel No 13/2018, process No 88887.717366/2022-00Deutsche Forschungsgemeinschaft FOR-2591, 321137804, "Severity Assessment in animal-based research"): M. Czaplik CZ 215/3-2, C. B. Pereira BA 7115/1-2, To 542/5-1, To 542/6-1.
6 · The paper itself

Abstract

The validation of methods for understanding the effects of many diseases and treatments requires the use of animal models in translational research. In this context, sheep have been employed extensively in scientific studies. However, the imposition of experimental conditions upon these animals may result in the experience of discomfort, pain, and stress. The ethical debates surrounding the use of animals in research have resulted in the adoption of Directive 2010/63/EU. The present study proposes a non-contact method for monitoring the respiration rate of sheep based on video processing. The Detecron2 model was trained to segment the sheep's body, abdominal, and facial regions in the video frames. A motion-tracking algorithm was developed to assess abdominal movement associated with the sheep's respiratory cycle. The method was applied to videos of Rhön sheep under experimental and housing conditions, utilising two types of cameras to assess the effectiveness of the proposed approach. The mean average error (MAE) obtained was 0.79 breaths/minute for the visible and 1.83 breaths/minute for the near-infrared (NIR) method. This study demonstrates the feasibility of video technology for simultaneous and non-invasive respiration monitoring, being a crucial parameter for assessing the health deterioration of multiple laboratory animals.

Indexed as

animal welfarerefinementrespiration ratesheep modelvideo signal processingwelfare assessment

Identifiers

PMID39682364
PMCPMC11639809

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.