ArticleOphthalmology and therapy2025
Long-Term Treatment Outcomes of Micropulse Transscleral Cyclophotocoagulation in Primary and Secondary Glaucoma: A 5-Year Analysis.
Article in Ophthalmology and therapy, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Outcomes of micropulse cyclophotocoagulation for refractory glaucoma in children.Japanese journal of ophthalmology · 2026Article
- Correlation between mid-term intraocular pressure and aqueous flare value in micropulse transscleral cyclophotocoagulation: a retrospective observational study.BMC ophthalmology · 2026Observational
- Micropulse Transscleral Cyclophotocoagulation in Refractory Glaucoma: Two-year Results of a Prospective Multicenter Study.Clinical ophthalmology (Auckland, N.Z.) · 2026Article
- Safety and efficacy of micropulse transscleral laser therapy for glaucoma: a two-year follow-up.International journal of ophthalmology · 2026Article
- Efficacy, Repeatability, and Safety of Retreatment with Micropulse Cyclophotocoagulation in the Management of Glaucoma.Ophthalmology and therapy · 2026Article
- Outcomes of micropulse transscleral cyclophotocoagulation using different sweep velocity in the treatment of refractory glaucoma.Scientific reports · 2025Article
- Thermal Tissue Modeling of the Ciliary Body With Continuous Wave Transscleral Cyclophotocoagulation and Transscleral Laser Therapy Using MicroPulse Technology.Translational vision science & technology · 2025Article
- Clinical Practice Preferences for Glaucoma Surgery in Japan in 2024.Journal of clinical medicine · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionTo investigate 5-year outcomes on intraocular pressure (IOP) and safety of micropulse transscleral cyclophotocoagulation (TSCPC) in patients with glaucoma.
methodsPatients with mild to advanced glaucoma who underwent a standardized micropulse TSCPC procedure at the University Eye Clinic Maastricht from November 2016 to February 2019 were included.
resultsA total of 165 eyes were included, with outcomes for 112 eyes available after 5-year follow-up. Mean age was 67.3 ± 13.9 years; 58.2% were male. Glaucoma subtypes were primary glaucoma (n = 108) and secondary glaucoma (n = 57). Prior glaucoma surgery was performed in 65 of 165 eyes (39.4%). In the primary glaucoma group, mean preoperative IOP was 20.7 ± 7.1 mmHg. Mean postoperative IOP at 1, 2, 3, 4, and 5 years significantly reduced to 15.2 ± 6.5, 14.3 ± 5.0, 14.0 ± 4.9, 13.5 ± 4.1, and 12.9 ± 4.3 mmHg, respectively. Preoperatively, the mean number of IOP-lowering medications was 3.3 ± 1.3, which changed to 2.8 ± 1.3, 2.8 ± 1.2, 2.8 ± 1.2, 2.9 ± 1.2, and 2.7 ± 1.3 at 1, 2, 3, 4, and 5 years, respectively. In the secondary glaucoma group, mean preoperative IOP was 28.7 ± 10.3 mmHg, dropping significantly to 19.3 ± 10.4, 18.6 ± 11.3, 17.8 ± 9.8, 18.1 ± 12.0, and 15.5 ± 7.6 mmHg at the same intervals. The number of IOP-lowering medication was significantly reduced from 3.5 ± 1.1 to 2.5 ± 1.5, 2.2 ± 1.5, 2.6 ± 1.4, 2.6 ± 1.5, and 2.5 ± 1.7. In the total group, mean IOP reduction was 32.5% after 5 years. Postoperative complications included cystic macular edema (n = 3), fibrinous/uveitic reaction (n = 1), and rejection of corneal graft (n = 2), all reversible after treatment. One patient developed late and persisting hypotony. Other adverse events were retinal venous occlusion (n = 1) and retinal vasculitis (n = 1), unrelated to the laser treatment. In patients with a preoperative Central Distance Visual Acuity (CDVA) > 0.05 on the Snellen chart, more than two lines of visual acuity (VA) loss were attributed to cataract (n = 10), retinal disease (n = 5), glaucoma progression (n = 3), corneal decompensation (n = 2), or other factors (n = 11).
conclusionMicropulse TSCPC is a safe and effective treatment for reducing IOP and the number of IOP-lowering medications after a 5-year follow-up period. It is a viable alternative for patients after failed incisional glaucoma surgery or high-risk patients.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.