Evidence map›Paper›PMID 39679179›Full record

ArticleNanophotonics (Berlin, Germany)2024

Wide FOV metalens for near-infrared capsule endoscopy: advancing compact medical imaging.

Mojtaba Moghaddasi, Erik Edilson Perez Coca, Danni Ye, Diego Alejandro Flores, Xudong Wu, Abdul Jalal, Ziming Ren, Fahimeh Abrinaei, Bin Hu

Abstract read
In one paragraph

Article in Nanophotonics (Berlin, Germany), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Compound Meta-Optics for Advanced Optical Engineering.Sensors (Basel, Switzerland) · 2026
    Review
  2. Article
  3. Review
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Mojtaba MoghaddasiNational Key Laboratory on Near-Surface Detection, School of Optics and Photonics, Beijing Institute of Technology, Beijing 100081, China.ORCID https://orcid.org/0009-0009-4646-8999
Erik Edilson Perez CocaSchool of Mechatronical Engineering, Beijing Institute of Technology, Beijing 100081, China.ORCID https://orcid.org/0009-0006-0928-2755
Danni YeSchool of Chinese Materia Medica, Beijing University of Chinese Medicine, Beijing 102488, China.ORCID https://orcid.org/0009-0003-2854-8086
Diego Alejandro FloresSchool of Computer Science and Technology, Beijing Institute of Technology, Beijing 100081, China.ORCID https://orcid.org/0009-0009-8878-7875
Xudong WuNational Key Laboratory on Near-Surface Detection, School of Optics and Photonics, Beijing Institute of Technology, Beijing 100081, China.
Abdul JalalNational Key Laboratory on Near-Surface Detection, School of Optics and Photonics, Beijing Institute of Technology, Beijing 100081, China.
Ziming RenNational Key Laboratory on Near-Surface Detection, School of Optics and Photonics, Beijing Institute of Technology, Beijing 100081, China.
Fahimeh AbrinaeiDepartment of Physics, Central Tehran Branch, Islamic Azad University, Tehran, Iran.
Bin HuNational Key Laboratory on Near-Surface Detection, School of Optics and Photonics, Beijing Institute of Technology, Beijing 100081, China.ORCID https://orcid.org/0000-0002-3315-8440

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study presents the design, fabrication, and characterization of a wide field-of-view (FOV) metalens optimized for capsule endoscopy. The metalens achieved a 165° FOV with a high modulation transfer function (MTF) of 300 lines per millimeter (lp/mm) across the entire FOV, operating in the near-infrared (NIR) narrow-bandpass imaging at 940 nm. The performance of the metalens-based system is evaluated using two bandwidths, 12 nm and 32 nm, showing MTF values of 0.2 and 0.3 at 250 lp/mm, respectively. The metalens-based system maintains a compact form factor with a total track length of 1.4 mm and a diameter of 1.58 mm. Compared to a traditional 108° FOV endoscope, the nano-optic capsule endoscope demonstrated superior performance in terms of FOV, contrast, and resolution. This advancement represents a significant step toward enhancing diagnostic capabilities in medical imaging, offering improved performance in a more compact package compared to conventional optics.

Indexed as

capsule endoscopymetalensmetasurfacenano-opticsnarrow band imagingwide field of view

Identifiers

PMID39679179
PMCPMC11636453

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.