Evidence map›Paper›PMID 39677409›Full record

ArticlePhotoacoustics2024

Dual-tube MEMS-based spectrophone for sub-ppb mid-IR photoacoustic gas detection.

Stefano Dello Russo, Jacopo Pelini, Inaki Lopez Garcia, Maria Concetta Canino, Alberto Roncaglia, Pablo Cancio Pastor, Iacopo Galli, Paolo De Natale, Simone Borri, Mario Siciliani de Cumis

Abstract read
In one paragraph

Article in Photoacoustics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. LITES-Based Sensitive COSensors (Basel, Switzerland) · 2025
    Article
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Stefano Dello RussoASI Agenzia Spaziale Italiana - Centro di Geodesia Spaziale, Località Terlecchia, Matera, 75100, Italy.
Jacopo PeliniCNR-INO - Istituto Nazionale di Ottica, and LENS, via N. Carrara 1, Sesto Fiorentino, 50019, Italy.
Inaki Lopez GarciaCNR-INO - Istituto Nazionale di Ottica, and LENS, via N. Carrara 1, Sesto Fiorentino, 50019, Italy.
Maria Concetta CaninoIstituto per la Microelettronica e Microsistemi (IMM) Consiglio Nazionale delle Ricerche (CNR), Via P. Gobetti 101, Bologna, 40129, Italy.
Alberto RoncagliaIstituto per la Microelettronica e Microsistemi (IMM) Consiglio Nazionale delle Ricerche (CNR), Via P. Gobetti 101, Bologna, 40129, Italy.
Pablo Cancio PastorCNR-INO - Istituto Nazionale di Ottica, and LENS, via N. Carrara 1, Sesto Fiorentino, 50019, Italy.
Iacopo GalliCNR-INO - Istituto Nazionale di Ottica, and LENS, via N. Carrara 1, Sesto Fiorentino, 50019, Italy.
Paolo De NataleCNR-INO - Istituto Nazionale di Ottica, and LENS, via N. Carrara 1, Sesto Fiorentino, 50019, Italy.
Simone BorriCNR-INO - Istituto Nazionale di Ottica, and LENS, via N. Carrara 1, Sesto Fiorentino, 50019, Italy.
Mario Siciliani de CumisASI Agenzia Spaziale Italiana - Centro di Geodesia Spaziale, Località Terlecchia, Matera, 75100, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Nowadays, the scientific community and industry are increasingly pressed to provide solutions for developing compact and highly-performing trace-gas sensors for several applications of crucial importance, such as environmental monitoring or medical diagnostics. In this context, this work describes a novel configuration, making use of a mid-IR spectrophone combining the compactness of a photo-acoustic setup, a non-conventional micro-electro-mechanical (MEMS) acousto-to-voltage transducer, and the sensitivity enhancement given by a cost-effective and easy-to-build dual-tube resonator configuration. In the optimal condition of sample pressure, the system developed in this work can achieve a minimum detection limit (MDL) equal to 0.34 ppb when averaging up to 10 s. Compared with previous literature of single-pass photoacoustic-based sensors for N

Indexed as

Acoustic enhancementDual tube configurationMicro-electro-mechanical system (MEMS)Minimum detection limitPhoto-acoustic spectroscopySub-part-per-billionTrace-gas sensor

Identifiers

PMID39677409
PMCPMC11639353

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.