Assessment of Ultraviolet-C Light for Sterilization of Hysteroscopy Instruments.
Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- A comparative study on the cleaning efficacy of a pulsed vacuum cleaning and disinfection device on rigid endoscopic instruments in a hospital setting.Frontiers in cellular and infection microbiology · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Objective To evaluate the sterilization efficacy of hysteroscopy instruments using ultraviolet C (UV-C) light at a wavelength of 259 nm in the Endoscopic Diagnostic Center of the National Institute of Perinatology. Methods Consecutive patients undergoing office hysteroscopy via the Bettochi vaginoscopy technique were included, excluding those with conditions such as viable intrauterine pregnancy or acute pelvic infection. Samples were collected from six designated sites of the hysteroscope, including the inner sheath, internal holes of the inner sheath, lens, graspers, scissors, and outer sheath. Initially, samples were taken after the first sterilization using a LAOKEN LK/MJG-150 Plasma Sterilizer (Chengdu, China). Next, samples were collected after the routine use of the hysteroscope in the office setting to confirm contamination. Subsequently, a new set of samples were taken after a 20-minute UV-C sterilization cycle with the EsteriUV device. Results The initial sterilization achieved a 96.73% sterilization rate, with ten samples testing positive for