Evidence map›Paper›PMID 39676422›Full record

ArticleAnnals of laboratory medicine2025

Artificial Intelligence in Diagnostics: Enhancing Urine Test Accuracy Using a Mobile Phone-Based Reading System.

Hyun Jin Kim, Manmyung Kim, Hyunjae Zhang, Hae Ri Kim, Jae Wan Jeon, Yuri Seo, Qute Choi

Abstract read
In one paragraph

Article in Annals of laboratory medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Hyun Jin KimDepartment of Laboratory Medicine, Chungnam National University School of Medicine, Daejeon, Korea.ORCID https://orcid.org/0000-0003-1725-2573
Manmyung KimRobosapiens, Inc., Daejeon, Korea.ORCID https://orcid.org/0009-0007-3901-0002
Hyunjae ZhangRobosapiens, Inc., Daejeon, Korea.ORCID https://orcid.org/0009-0000-8031-6723
Hae Ri KimDepartment of Laboratory Medicine, Chungnam National University School of Medicine, Daejeon, Korea.ORCID https://orcid.org/0000-0001-8766-6064
Jae Wan JeonDepartment of Laboratory Medicine, Chungnam National University School of Medicine, Daejeon, Korea.ORCID https://orcid.org/0000-0003-4256-3672
Yuri SeoDepartment of Family Medicine, Chungnam National University Sejong Hospital, Sejong, Korea.ORCID https://orcid.org/0000-0001-6371-4025
Qute ChoiDepartment of Laboratory Medicine, Chungnam National University School of Medicine, Daejeon, Korea.ORCID https://orcid.org/0000-0002-8520-3119

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Urinalysis, an essential diagnostic tool, faces challenges in terms of standardization and accuracy. The use of artificial intelligence (AI) with mobile technology can potentially solve these challenges. Therefore, we investigated the effectiveness and accuracy of an AI-based program in automatically interpreting urine test strips using mobile phone cameras, an approach that may revolutionize point-of-care testing. Methods: We developed novel urine test strips and an AI algorithm for image capture. Sample images from the Chungnam National University Sejong Hospital were collected to train a k-nearest neighbor classification algorithm to read the strips. A mobile application was developed for image capturing and processing. We assessed the accuracy, sensitivity, specificity, and ROC area under the curve for 10 parameters. Results: In total, 2,612 urine test strip images were collected. The AI algorithm demonstrated 98.7% accuracy in detecting urinary nitrite and 97.3% accuracy in detecting urinary glucose. The sensitivity and specificity were high for most parameters. However, this system could not reliably determine the specific gravity. The optimal time for capturing the test strip results was 75 secs after dipping. Conclusions: The AI-based program accurately interpreted urine test strips using smartphone cameras, offering an accessible and efficient method for urinalysis. This system can be used for immediate analysis and remote testing. Further research is warranted to refine test parameters such as specific gravity to enhance accuracy and reliability.

Indexed as

Artificial IntelligenceCell PhoneUrinalysisAlgorithmsArea Under CurveGlucoseHumansMobile ApplicationsNitritesROC CurveSensitivity and SpecificitySmartphoneGlucoseNitritesArtificial intelligenceMobile applicationSmartphoneUrinalysis

Identifiers

PMID39676422
PMCPMC11788702

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.