Evidence map›Paper›PMID 39675026›Full record

ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2025

Fixation of Takeuchi Type II/III lateral hinge fractures provides favourable stability of a medial open wedge high tibial osteotomy-A biomechanical study.

Christian Peez, Adrian Deichsel, Ivan Zderic, R Geoff Richards, Ludmil Drenchev, Hristo K Skulev, Boyko Gueorguiev, Michael J Raschke, Christoph Kittl, Elmar Herbst

Abstract read
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Christian PeezAO Research Institute Davos, Davos, Switzerland.ORCID http://orcid.org/0000-0001-8055-289X
Adrian DeichselDepartment of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Münster, Germany.
Ivan ZdericAO Research Institute Davos, Davos, Switzerland.ORCID https://orcid.org/0000-0003-0484-887X
R Geoff RichardsAO Research Institute Davos, Davos, Switzerland.ORCID https://orcid.org/0000-0002-7778-2480
Ludmil DrenchevBulgarian Academy of Sciences, Institute of Metal Science "Acad. A. Balevski", Sofia, Bulgaria.
Hristo K SkulevBulgarian Academy of Sciences, Institute of Metal Science "Acad. A. Balevski", Sofia, Bulgaria.
Boyko GueorguievAO Research Institute Davos, Davos, Switzerland.ORCID https://orcid.org/0000-0001-9795-115X
Michael J RaschkeDepartment of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Münster, Germany.
Christoph KittlDepartment of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Münster, Germany.
Elmar HerbstDepartment of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Münster, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo investigate the biomechanical consequences of osteosynthesis of lateral hinge fractures (LHFs) in medial open wedge high tibial osteotomy (MOWHTO).

methodsSixteen fresh-frozen human cadaveric proximal tibiae underwent MOWHTO fixed with an ipsilateral locking compression plate. The specimens were assigned to two clusters simulating LHFs according to the Takeuchi classification: (1) Type II fracture; and (2) Type III fracture. The following conditions were serially tested: (1) intact hinge; (2) fractured hinge; (3) screw fixation of the LHF; (4) staple fixation of the LHF; and (5) locking T-plate fixation of the LHF. Each specimen was subjected to 10 cycles of axial compression load (720 N; 36 N/s), and internal and external rotational loads (10 N m; 1 N m/s), while capturing the interfragmentary movements via motion tracking.

resultsIn Takeuchi Type II fractures, osteosynthesis of the fractured hinge with staples or a plate significantly reduced fracture site displacement (p < 0.05) and significantly increased construct stiffness (p < 0.05) under axial and torsional loading, while only the plate restored intact torsional displacement (n.s.). For Takeuchi Type III fractures, both screw and plate fixation significantly reduced fracture site displacement (p < 0.05) and significantly increased construct stiffness (p < 0.05) under axial and torsional loading. Both techniques restored torsional stiffness in each rotational direction and torsional displacement in internal rotation (n.s.).

conclusionAdditional plate fixation of Takeuchi Type II fractures was the construct with the highest stiffness, restoring the axial and torsional stability to a MOWHTO with an intact hinge. Screw and plate fixation of Takeuchi Type III fractures provided equivalent stability and restored the torsional and axial stability of the MOWHTO. In case of a Takeuchi Type II or III fracture, surgeons should consider additional plate or screw osteosynthesis of the fractured hinge to best restore the stability of the MOWHTO, which may potentially reduce the risk of loss of correction and impaired bone healing. LEVEL OF EVIDENCE: There is no level of evidence as this study was an experimental laboratory study.

Indexed as

Fracture Fixation, InternalOsteotomyTibiaTibial FracturesAgedAged, 80 and overBiomechanical PhenomenaBone PlatesBone ScrewsCadaverFemaleHumansMaleMiddle Agedlateral hinge fracturesmedial open wedge high tibial osteotomymotion trackingplatescrewTakeuchi classificationtorsional instability

Identifiers

PMID39675026
PMCPMC11948176

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.