ArticlePloS one2024
Application of Simodont virtual simulation system for preclinical teaching of access and coronal cavity preparation.
Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Influence of virtual reality simulation (excluding augmented reality) on endodontic learning experiences of undergraduate dental students: a systematic review.BMC medical education · 2025Pooled it
- The landscape of virtual simulation in undergraduate dental education with implications for artificial intelligence incorporation.NPJ digital medicine · 2026Article
- Evaluation of a Haptic Virtual Reality Simulator and Its Impact on Preclinical Dental Education.Cureus · 2026Article
- Stage of manual skill acquisition with Simodont virtual reality simulator for pre-clinical dental training: an interventional matching study.BMC medical education · 2026Article
- Application and development of artificial intelligence and immersive technologies in dental education: a scoping review.BMC medical education · 2025Article
- Evaluation of a virtual simulation system for root canal irrigation training in preclinical dental education.BMC medical education · 2025Article
- Intelligent Dental Handpiece: Real-Time Motion Analysis for Skill Development.Sensors (Basel, Switzerland) · 2025Article
- Evaluation of the Application of a Dental Virtual Simulator to Pre-Clinical Pediatric Dental Training.Advances in medical education and practice · 2025Article
- A comparative analysis of perceptions and evaluations of Simodont® Dental Trainer: a decade of virtual simulation.Frontiers in oral health · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
To explore the quality, reliability, and practical effect of the Simodont virtual simulation training system in preclinical teaching of access and coronal cavity preparation for dental undergraduate students. Twenty dental undergraduate students from Guanghua School of Stomatology, Sun Yat-sen University, were recruited and randomly divided into two groups after theory training. The groups were allocated using the random number method and assessed for access and coronal cavity preparation skills using a standardized assessment form and the Simodont virtual simulation system operation manual. Baseline scores were recorded for each student. One group received training with the Simodont virtual simulation system, while the other used a conventional phantom simulator system. After training, skills were reassessed, and scores were recorded. The groups then switched training systems and were assessed again. All students completed a Teaching Questionnaire at the end of the training. Data was collected and analyzed. The mean score of students in the virtual simulation priority group (15.9 ± 0.56 points) and the phantom-simulator priority group (15.3 ± 0.40 points) was significantly higher than the baseline score (13.3 ± 0.63 points) and (13.1 ± 0.30 points) (P < 0.05), respectively. Furthermore, the mean score of students in the virtual simulation priority group after training with both systems (15.9 ± 0.56 points) was significantly higher than that of the students in the virtual simulation priority group alone (14.2 ± 0.62 points) (P < 0.05). The mean score was also significantly higher in the virtual simulation priority group of students (15.9 ± 0.56 points) trained with both systems than in the phantom-simulator priority group of students (15.3 ± 0.40 points) trained with both systems for the assessment (p < 0.05). The mean score of students in the phantom-simulator priority group (15.3 ± 0.40 points) after training with both systems was significantly higher than that of the students in the phantom-simulator priority group alone (14.3 ± 0.28 points) (P < 0.05). The questionnaire results showed that the students fully agreed that "the Simodont virtual simulation system has the characteristics of repeatability, multi-dimensionality, and multiple practices, and gives me more attention to details. However, they also noted that "it needs to be improved and upgraded to be closer to the conventional phantom-simulator system. Compared with the conventional phantom-simulator system alone, the preclinical teaching effectiveness of access and coronal cavity preparation could be significantly enhanced by incorporating the Simodont virtual simulation system alongside the phantom-simulator training system. The training sequence might influence this improvement.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.