Evidence map›Paper›PMID 39671356›Full record

ArticlePloS one2024

Evaluation of the performance of a qPCR-based assay for HIV-1 viral load determination.

Bin Lin, Chao Han, Jin-Hai Li, Rui Wang

Abstract readEvaluation Study
In one paragraph

Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Cells · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Bin LinDivision of HIV/AIDS Control and Prevention, Shandong Center for Disease Control and Prevention, Jinan, Shandong Province, China.ORCID 0000-0002-4643-3050
Chao HanClinical Laboratory, Zibo Center for Disease Control and Prevention, Zibo, Shandong Province, China.
Jin-Hai LiDivision of HIV/AIDS Control and Prevention, Shandong Center for Disease Control and Prevention, Jinan, Shandong Province, China.
Rui WangDepartment of Anesthesiology, Qilu Hospital of Shandong University, Jinan, Shandong Province, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveAccording to the YY/T 1182-2010 standard of the People's Republic of China on nucleic acid amplification test reagents (kits) for medical industry, the accuracy, precision, linear range, and analytic sensitivity of HIV-1 standardized quality control products should be assessed. The Geneway HIV-1 Nucleic Acid Detection Kit from China has been successfully registered with the National Medical Products Administration. Here, we aimed to assess for the first time its detection performance.

methodsThe accuracy, precision, analytic sensitivity, and linearity of the Geneway HIV-1 nucleic acid quantification test kit were analyzed using a series of diluted standard control samples of HIV-1 negative plasma. Clinical plasma samples were collected from 163 HIV-infected patients and 38 HIV-negative patients. The detection performance of the Geneway assay was compared with that of the US FDA-approved COBAS AmpliPrep/COBAS® Taqman® HIV-1 test (Roche), version 2.0, for viral load (VL) monitoring.

resultsThe absolute deviation of the assay between the logarithm of the measured concentration and the logarithm of the expected concentration did not exceed ±0.5 logarithmic units. All coefficients of variation (CV%) for the assays were within 5%, indicating good precision in the detection. The linearity of quantitation was excellent (r = 0.999). Overall agreement was observed in 198 of the 201 specimens (98.51%), with a kappa value of 0.953. Bland-Altman analysis revealed an average difference of 0.030 between the two assays, with 95.95% (142/148) of the differences falling within the 95% confidence limits of agreement (-0.50, 0.56). Linear regression results demonstrated a strong linear correlation between the two assays, with a high Pearson correlation coefficient (r = 0.980) and coefficient of determination (R2 = 0.960, p < 0.001).

conclusionsThe Geneway HIV-1 VL assay demonstrated excellent accuracy, precision, analytic sensitivity, and linearity. Compared to the Roche assay, the Geneway assay showed good performance for HIV-1 VL detection, supporting its use in clinical practice.

Indexed as

HIV-1HIV InfectionsReal-Time Polymerase Chain ReactionViral LoadChinaHumansReagent Kits, DiagnosticReproducibility of ResultsRNA, ViralSensitivity and SpecificityReagent Kits, DiagnosticRNA, Viral

Identifiers

PMID39671356
PMCPMC11642942

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.