ArticlePhotoacoustics2024
A multi-aperture encoding scheme for increased SNR in photoacoustic Imaging.
Article in Photoacoustics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Advances and Challenges of Capacitive Micromachined Ultrasonic Transducers in Medical Imaging.Micromachines · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Photoacoustic imaging creates light-induced ultrasonic signals to provide valuable information on internal body structures and tissue morphology non-invasively. A multi-aperture photoacoustic imaging (MP-PAI) system is an improvement over conventional photoacoustic imaging (PAI) systems in terms of resolution, contrast, and field of view. Previously, a prototype MP-PAI system was introduced based on multiple capacitive micromachined ultrasound transducers (CMUTs) with shared channels, such that each element in a CMUT shares its channel with its counterpart in other CMUTs. The system uses the biasing voltages of the CMUTs to switch between them and multiplex the received signals in time. Notwithstanding all the enhancements, the signal-to-noise ratio (SNR) remains limited in PAI. To address this issue, we are proposing a multi-aperture encoding scheme (MAES) to further increase the SNR in a multi-aperture PAI system. The proposed method involves receiving signals with multiple CMUTs simultaneously based on an encoding matrix, instead of switching between individual CMUTs. As a result, shared channels contain a superposition of signals, which are later recovered by applying a decoding matrix. Here, an analytical model for computing SNR with an arbitrary encoding sequence is presented, and the method is validated through numerical simulations and in an experimental study. Bipolar and unipolar encoding sequences were considered for the experiments. The numerical results show, in comparison to conventional MP-PAI, that MAES will obtain an SNR gain of 5.8 and 8.8 dB for S-sequence and truncated Hadamard encodings, respectively, when using 15 transducers. In experiments, three transducers are encoded by S-sequences and show 1.5 dB improvement in SNR over conventional MP-PAI method, which aligns well with the analytical model.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.