Evidence map›Paper›PMID 39670052›Full record

ArticleStructural heart : the journal of the Heart Team2024

Concept, Design, and Preclinical Testing of a Remote-Control Robotic System for Transesophageal Echocardiography.

Jury Schewel, Ryan D Madder, Dimitry Schewel

Abstract read
In one paragraph

Article in Structural heart : the journal of the Heart Team, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Current and future applications of robotics in structural heart interventions.EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2025
    Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Jury SchewelMarienkrankenhaus Hamburg gGmbH, Department for Cardiology, Angiology, and Intensive Care, Hamburg, Germany.
Ryan D MadderFrederik Meijer Heart & Vascular Institute, Grand Rapids, Michigan, USA.
Dimitry SchewelMarienkrankenhaus Hamburg gGmbH, Department for Cardiology, Angiology, and Intensive Care, Hamburg, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Interventional echocardiography (IE) plays a critical role in guiding structural heart interventions. IE specialists face challenges including high radiation exposure and unfavorable ergonomics. To address these issues, a novel remote-control robotic (RCR) system for transesophageal echocardiography (TEE) control has been developed. This study aims to describe the novel RCR system and to assess its performance in bench tests and in vitro models in terms of functionality, image quality, and reproducibility. Methods: Bench testing and in vitro testing were performed using the RCR system. All tests were performed using the GE 6VT-D TEE probe and the GE Vivid E95. Results: Key findings include proof of concept through bench testing, remote control of all five degrees of freedom of the TEE probe, and reliable, fast, and accurate reproducibility using automated navigation. The ROB'E Base is securely attached to the operating table, optimizing the footprint in the operating room. The ROB'E Guide accurately performs the forward and backward motion of the flexible portion of the TEE probe, stabilizing the achieved positions and preventing twisting during rotation. The ROB'E RCR system can store and reproduce TEE probe positions and has demonstrated reliable and accurate automated reproducibility in both bench and in vitro tests. Conclusions: The ROB'E RCR system for TEE overcomes the limitations of conventional IE by using a RCR approach that eliminates the need for the echocardiographer to be physically present in the operating room. Thus, it significantly reduces radiation exposure and demonstrates its capabilities to improve image quality, reproducibility, and overall safety in IE.

Indexed as

Artificial intelligenceAutomationDiagnosticsEchocardiographic guidanceEchocardiographyGuidingHeart valve diseaseImagingIntraprocedural imagingRadiationRoboticScreeningStructural heart interventionsUltrasound

Identifiers

PMID39670052
PMCPMC11633039

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked