Evidence map›Paper›PMID 39668531›Full record

ArticleUlusal travma ve acil cerrahi dergisi = Turkish journal of trauma & emergency surgery : TJTES2024

Finite element analysis of intramedullary nailing and nail-plate combinations for treating unstable proximal tibial metaphyseal fractures.

Sefa Toksoy, Idris Demirtaş, Musa Güngörürler, Volkan Öztuna

Abstract read
In one paragraph

Article in Ulusal travma ve acil cerrahi dergisi = Turkish journal of trauma & emergency surgery : TJTES, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Observational
  2. [Treatment options and research progress of proximal tibial extra-articular fractures].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2025
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Sefa ToksoyDepartment of Orthopedics and Traumatology, Mut State Hospital, Mersin-Türkiye.
Idris DemirtaşDepartment of Orthopedics and Traumatology, Mersin Training and Research State Hospital, Mersin-Türkiye.
Musa GüngörürlerDepartment of Biomechanics, School of Medicine Health Science Institute, Dokuz Eylul University, İzmir-Türkiye.
Volkan ÖztunaDepartment of Orthopedics and Traumatology, Mersin VM Medical Park Hospital, Mersin-Türkiye.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe anatomy of the proximal tibia presents treatment challenges, and there is currently no widely accepted surgical fixation method for fractures in this region. The aim of this study is to evaluate the efficacy, benefits, and differences between intramedullary nailing (IMN) with a 4-hole Limited Contact Dynamic Compression Plate (LC-DCP) combination and IMN with an 8-hole LC-DCP combination in unstable fractures of the proximal metaphyseal region of the tibia.

methodsAn oblique fracture was created in the metaphyseal region, forming a 30-degree angle in the sagittal plane in three tibial models. The fracture was designed to be 5 cm distal to the knee joint anteriorly and 8 cm distal to the knee joint posteriorly. One model was fixed with intramedullary nailing alone, while the others received additional fixation with either a 4-hole or an 8-hole plate in addition to the nail. Finite element analysis was performed using 3D computed tomography images of the models. Deformation, displacement, von Mises stress, and maximum principal strain values resulting from axial, lateral, coronal, and rotational forces applied to the models were analyzed.

resultsThe model fixed with intramedullary nailing alone demonstrated greater maximum stress, maximum deformation, and displacement under all applied forces. In the model with nail and 8-hole plate, unlike the other models, the highest amount of stress in the nail was concentrated on the distal locking screw under axial force. We observed that the maximum principal strain in the tibia was higher in the models with combined nail and plate fixation than in the model with intramedullary nailing alone.

conclusionThe results of this study indicate that the combination treatment with an 8-hole DCP plate is biomechanically superior for treating unstable proximal tibial fractures with nails. Although the nail-plate combination requires an additional surgical incision and extra implants, it provides advantages in terms of stability and the sustainability of fracture reduction in unstable fractures.

Indexed as

Bone NailsBone PlatesFinite Element AnalysisFracture Fixation, IntramedullaryTibial FracturesBiomechanical PhenomenaHumans

Identifiers

PMID39668531
PMCPMC11849876

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.