Evidence map›Paper›PMID 39668281›Full record

Observational studyTechniques in coloproctology2024

Quantification of indocyanine-green-enhanced fluorescence with spectrophotometry (O2C®) in low anterior rectal resection: A prospective study.

I Darwich, S Demirel-Darwich, C Weiss, F Willeke

Abstract readObservational Study
In one paragraph

Observational study in Techniques in coloproctology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

I DarwichDepartment of Surgery, St. Marienkrankenhaus Siegen, Kampenstr. 51, 57072, Siegen, Germany. Ibrahim@darwich.net.
S Demirel-DarwichDepartment of Surgery, St. Marienkrankenhaus Siegen, Kampenstr. 51, 57072, Siegen, Germany.
C WeissDepartment of Medical Statistics, Biomathematics, and Information Processing at the University Medical Center Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany.
F WillekeDepartment of Surgery, St. Marienkrankenhaus Siegen, Kampenstr. 51, 57072, Siegen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionDespite spectacular visuals and the seemingly convincing rationale of using indocyanine-green-enhanced fluorescence in assessing bowel perfusion during colorectal resections, a lingering sense of subjectivity remains in the challenge of quantifying this fluorescence. This prospective study analyzed the application of O2C® spectrophotometry to quantify zones of fluorescence on the large bowel during low anterior resection. MATERIALS AND

methodsPatients receiving a low anterior resection for cancer of the mid- and lower rectum were enrolled in this observational prospective study between February 2020 and December 2022. O2C® blood-flow measurement was performed at three different zones of fluorescence intensity (optimal [O], sufficient [S], and absent [A]), visualized at the designated and already skeletonized site of colon transection. The primary end point was to assess whether the O2C® flow value exceeds 164 arbitrary units (AU) at the zone of optimal fluorescence. The secondary objective was to assess whether there were statistically significant differences in flow parameters between the three zones, thus confirming reproducibility of measurements.

resultsA total of 40 patients were enrolled in this study. Of these, 38 patients remained for statistical analysis with regard to O2C® measurement of the fluorescence zones. The O2C® flow parameter measured at the zone of optimal fluorescence was greater than 164 AU in all cases (100%, p < 0.0001). There were statistically significant differences in flow parameters measured at the three different zones of fluorescence (O-S: p < 0.0001; O-A: p < 0.0001; S-A: p = 0.0023).

conclusionThis study proves the feasibility and reproducibility of quantifying zones of indocyanine green (ICG)-enhanced fluorescence on the bowel. All O2C® flow measurements that were collected at the zone of optimal fluorescence exceeded 164 AU, thereby adding more evidence to this value as a suggested cut-off parameter in terms of bowel perfusion.

Indexed as

Indocyanine GreenProctectomyRectal NeoplasmsAgedAged, 80 and overColoring AgentsFemaleFluorescenceHumansMaleMiddle AgedProspective StudiesRectumReproducibility of ResultsSpectrophotometryColoring AgentsIndocyanine GreenAnastomotic leakBowel perfusionCold steel testColic marginal arteryFluorescenceICGLow anterior resectionO2C®

Identifiers

PMID39668281
PMCPMC11638411

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.