Evidence map›Paper›PMID 39666081›Full record

ArticleArchives of orthopaedic and trauma surgery2024

Mid- to long-term clinical and radiological assessment of a short, titanium, porous plasma-splayed flat-tapered cementless femoral stem: An 8- to 12-year follow-up study.

Kensuke Yoshino, Yoshitada Harada, Jin Miyagi, Yuya Ogawa, Akito Nagai

Abstract read
PubMed Publisher
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Kensuke YoshinoDepartment of Orthopaedic Surgery, Chibaken Saiseikai Narashino Hospital, 1-1-1 Izumi-cho, Narashino city, 275-8580, Chiba, Japan. knskysn@gmail.com.ORCID http://orcid.org/0000-0003-3543-5074
Yoshitada HaradaDepartment of Orthopaedic Surgery, Chibaken Saiseikai Narashino Hospital, 1-1-1 Izumi-cho, Narashino city, 275-8580, Chiba, Japan.
Jin MiyagiDepartment of Orthopaedic Surgery, Chibaken Saiseikai Narashino Hospital, 1-1-1 Izumi-cho, Narashino city, 275-8580, Chiba, Japan.
Yuya OgawaDepartment of Orthopaedic Surgery, Chibaken Saiseikai Narashino Hospital, 1-1-1 Izumi-cho, Narashino city, 275-8580, Chiba, Japan.
Akito NagaiDepartment of Orthopaedic Surgery, Chibaken Saiseikai Narashino Hospital, 1-1-1 Izumi-cho, Narashino city, 275-8580, Chiba, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionShort cementless stems offer advantages such as bone-stock preservation and minimally invasive insertion. Despite encouraging short- to midterm outcomes, the long-term clinical and radiological implications of short, titanium, and porous plasma-sprayed flat-tapered stems remain unclear. MATERIALS AND

methodsA retrospective review of 138 primary total hip arthroplasties, conducted between 2010 and 2015 in 130 patients, with a minimum 8-year follow-up was performed. Patients with Dorr type A or B femora were included. Clinical and radiographic results, complications, and survival rates were evaluated.

resultsA total of 102 hips (94 patients) were reviewed with complete clinical and radiographic data at a minimum 8-year follow-up (mean, 9.5 years). The modified Harris hip score significantly improved from a mean preoperative value of 40.1 to 97.8 at the final follow-up, with 91% of the hips achieving a score of ≥ 90. In the original cohort of 138 hips, none underwent revision surgery for symptomatic loosening. Perioperative complications occurred in eight hips, including femoral fractures, postoperative dislocation, subcutaneous abscess, and transient thigh pain. Radiographically, femoral stem alignment was predominantly neutral in 86% of the hips in the anteroposterior plane. No hip exhibited radiolucency > 1 mm, and no subsidence > 2 mm was observed. Bone ingrowth fixation was observed in all 102 hips. Stress shielding around or below the lesser trochanter occurred in 58% of hips. Kaplan-Meier survival analysis indicated a 100% survival rate at eight, 10, and 12 years for stem revision or radiological instability.

conclusionsThe short, titanium, porous, plasma-sprayed, flat-tapered cementless stem exhibited excellent mid- to long-term results in primary total hip arthroplasties with Dorr type A or B femora, comparable with those of other short cementless and standard-length stems. Noteworthy survivorship was observed; however, caution is advised regarding stress-shielding complications, particularly periprosthetic femoral fractures, during extended follow-up.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisProsthesis DesignTitaniumAdultAgedAged, 80 and overFemaleFemurFollow-Up StudiesHumansMaleMiddle AgedPorosityRadiographyRetrospective StudiesTitaniumClinical resultsMid-termShort cementless stemStress shieldingSurvival rateTotal hip arthroplasty

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.