ArticleJournal of clinical orthopaedics and trauma2024
Novel technique for achieving the under-correction of native tibial varus in calipered restricted kinematically aligned total knee arthroplasty - A validation study.
Article in Journal of clinical orthopaedics and trauma, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
- Erratum issued
- Erratum issued
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: Restricted kinematic alignment (rKA) TKA is relatively newer technique for achieving an overall under-corrected limb alignment. The present study aims to provide an easy and reproducible technique for achieving calipered rKA-TKA (crKA-TKA) using routine instrumentation. Method: A prospective study was conducted including 30 patients (30 knees). All patients underwent crKA-TKA by the same surgeon. Pre-operatively all patients underwent long film standing radiographs, and coronal angles were measured to plan tibial bony cuts and the femoral axis angle (FAA) to restore tibial varus under correction and native distal femoral anatomy, respectively. Intra-operatively while taking tibial cuts, the alignment rod was noted to be always pointing towards the "third metatarsal" of the ipsilateral foot. Results: 30 patients underwent total knee replacement with crKA technique. Angular corrections were satisfactory with all patients reaching the target MPTA of 87.48 ± 0.78 and LDFA of 90.301 ± 2.66 as planned, with an overall under-corrected limb alignment. HKA was achieved within a target of < ± 3 degrees of the native knee (3.56 ± 1.29). Post-operative radiological parameters were checked by two separate observers with excellent intra-class correlation coefficients. Conclusion: The present study validates a novel intra-operative technique of confirming an under-corrected native tibial varus while performing crKA-TKA. The radiological outcomes of the study confirm that with careful pre-operative planning, coronal angular targets were easily achievable with very less outliers. Study further establishes that this method of calipered technique in rKA-TKA using routine digital templating software and standard instrumentations is an alternative method of executing rKA. Level of evidence: IV, Prospective case series.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.