Evidence map›Paper›PMID 39664455›Full record

ArticleTransfusion medicine and hemotherapy : offizielles Organ der Deutschen Gesellschaft fur Transfusionsmedizin und Immunhamatologie2024

Cell Salvage Using the Autotransfusion Device CATSmart

Sven Arends, Michael Thomas, Michael Nosch, Thomas Droll, Denise Zwanziger, Thorsten Brenner, Ali Haddad

Abstract read
In one paragraph

Article in Transfusion medicine and hemotherapy : offizielles Organ der Deutschen Gesellschaft fur Transfusionsmedizin und Immunhamatologie, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Sven ArendsDepartment of Anesthesiology and Intensive Care Medicine, University Hospital Essen, University Duisburg-Essen, Essen, Germany.
Michael ThomasDepartment of Anesthesiology, Intensive Care Medicine, and Pain Therapy, Marien Hospital Bottrop gGmbH, Bottrop, Germany.
Michael NoschDepartment of Anesthesiology, Intensive Care Medicine, and Pain Therapy, Marien Hospital Bottrop gGmbH, Bottrop, Germany.
Thomas DrollDepartment of Anesthesiology and Intensive Care Medicine, University Hospital Essen, University Duisburg-Essen, Essen, Germany.
Denise ZwanzigerDepartment of Endocrinology, Diabetology und Metabolism, Clinical Chemistry - Division of Laboratory Research, University Hospital Essen, University Duisburg-Essen, Essen, Germany.
Thorsten BrennerDepartment of Anesthesiology and Intensive Care Medicine, University Hospital Essen, University Duisburg-Essen, Essen, Germany.
Ali HaddadDepartment of Anesthesiology and Intensive Care Medicine, University Hospital Essen, University Duisburg-Essen, Essen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The use of cell salvage and autologous blood transfusion is an important and widespread method of blood conservation during surgeries with expected high blood loss. The continuous autotransfusion device CATSmart Methods: In total, 69 patients undergoing cardiac or orthopedic surgery were included in this randomized, controlled, bicentric trial to validate the red cell separation process and washout quality of Flex wash 3 compared to Flex wash 5. After washing, the primary quality target was to determine hematocrit value, recovery rate, albumin, and total protein elimination rate in the packed red cells (PRCs). The secondary objective was to assess the elimination of heparin by measuring the factor anti-Xa activity by a 1- and 2-stage assay in PRC after washing. Results: In the whole cohort of patients, hematocrit was 16.00% [9.15%; 21.30%] (median [Q1; Q3]) in the wound blood and 69.90% [51.10%; 80.90%] in the PRC resulting in a recovery rate of 63.92% [47.06%; 88.13%]. The albumin elimination rate was 98.77% [97.94%; 99.27%], and the total protein elimination rate was 98.85% [97.76%; 99.42%]. The heparin elimination rate was 99.95% [99.90%; 99.97%] in the 1-stage assay and 99.70% [99.41%; 99.87%] in the 2-stage assay. There was no difference between Flex wash 3 and Flex wash 5 washing procedure regarding the recovery rate 63.75% [46.64%; 78.65%] versus 67.89% [47.20%; 92.69%] ( Conclusions: The two new washing procedures, Flex wash 3 and Flex wash 5, enable sufficient and comparable red cell separation and washout quality of albumin, total protein, as well as heparin.

Indexed as

AutotransfusionCATSmart®Flex washIntraoperative cell salvageTransfusionWashing program

Identifiers

PMID39664455
PMCPMC11631003

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.