Electrical cardiometry for non-invasive cardiac output monitoring: a method comparison study in patients after coronary artery bypass graft surgery.

Gillis Greiwe, Rami Saad, Alexander Hapfelmeier, Niklas Neumann, Pischtaz Tariparast, Bernd Saugel, Moritz Flick

Registry-linked trialAbstract readComparative Study
In one paragraph

Article in Journal of clinical monitoring and computing, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07109206 (Cardio-circulatory and Respiratory Monitoring for Prediction of Outcome in Mechanically Ventilated Chronic Obstructive Pulmonary Disease Patients), which is not on this map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT07109206 not yet recruitingnot on this map

Cardio-circulatory and Respiratory Monitoring for Prediction of Outcome in Mechanically Ventilated Chronic Obstructive Pulmonary Disease Patients

TypeobservationalSponsorAssiut UniversityRan2025 to 2028Enrolled104ConditionsCOPD (Chronic Obstructive Pulmonary Disease), Cardiometry, Weaning Invasive Mechanical Ventilation
3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Gillis Greiwe *Department of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany. g.greiwe@uke.de.
Rami Saad *Department of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany.
Alexander HapfelmeierInstitute of AI and Informatics in Medicine, TUM School of Medicine and Health, Technical University of Munich, Munich, Germany.
Niklas NeumannDepartment of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany.
Pischtaz TariparastDepartment of Intensive Care Medicine, Center of Anesthesiology and Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
Bernd SaugelDepartment of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany.
Moritz FlickDepartment of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Cardiac output can be estimated non-invasively by electrical cardiometry with the ICON® monitor (Osypka Medical GmbH, Berlin, Germany). Conflicting results have been reported regarding the cardiac output measurement performance of electrical cardiometry. In this prospective method comparison study, we compared cardiac output measured using electrical cardiometry (EC-CO; test method) with cardiac output measured using intermittent pulmonary artery thermodilution (PATD-CO; reference method) in patients after coronary artery bypass graft (CABG) surgery. We calculated the mean of the differences with 95%-limits of agreement (95%-LOA) and their corresponding 95%-confidence intervals (95%-CI) using Bland-Altman analysis and calculated the percentage error. We also analyzed trending using four-quadrant plot analysis. We analyzed 157 paired cardiac output measurements of 41 patients. Mean ± standard deviation PATD-CO was 5.1 ± 1.3 L/min and mean EC-CO was 5.3 ± 1.3 L/min. The mean of the differences ± SD between PATD-CO and EC-CO was -0.2 (95%-CI -0.5 to 0.2) ± 1.2 L/min with a lower 95%-LOA of -2.6 (95%-CI -3.1 to -2.0) L/min and an upper 95%-LOA of 2.3 (95%-CI 1.6 to 2.9) L/min. The percentage error was 47% (95%-CI, 37 to 56%). The concordance rate for cardiac output changes was 48%. In this study, the agreement between EC-CO and PATD-CO was not clinically acceptable in patients after CABG surgery. The trending ability of EC-CO was poor.

Indexed as

Cardiac OutputCoronary Artery BypassAgedFemaleHumansMaleMiddle AgedMonitoring, PhysiologicProspective StudiesPulmonary ArteryReproducibility of ResultsThermodilutionCardiac outputElectrical cardiometryHemodynamic monitoringPulmonary artery catheterPulmonary artery thermodilutionThoracic electrical bioimpedance

Identifiers

PMID39661264
PMCPMC12049288

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.