Evidence map›Paper›PMID 39659358›Full record

ArticleCureus2024

The Multichannel Intraoesophageal Impedance Transit Concept.

Ismail Miah, Terry Wong, Sebastian Zeki, Jafar Jafari

Abstract read
In one paragraph

Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Ismail MiahFaculty of Life Sciences and Medicine, King's College London, London, GBR.
Terry WongFaculty of Life Sciences and Medicine, King's College London, London, GBR.
Sebastian ZekiFaculty of Life Sciences and Medicine, King's College London, London, GBR.
Jafar JafariFaculty of Life Sciences and Medicine, King's College London, London, GBR.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction/aims The multichannel intraoesophageal impedance transit (MIIT) is a new clinical concept that is being introduced to measure the oesophageal transit during a 24-hour multichannel impedance-pH (MII-pH) study. Methods MIIT was tested in a case-control study between January 2020 and December 2023. A laboratory test was first conducted to determine the saline baseline impedance (SBI) using MII-pH catheters. SBI was later used to reference the oesophageal transit of saline during the MIIT test. In the MIIT test, patients rapidly drank 200 ml of saline within 20 seconds. The saline transit was identified by the temporal impedance changes from the oesophageal mucosal baseline impedance (MBI) to the approximate SBI level. The duration of SBI was recorded from multiple impedance sensors in the proximal, mid and distal oesophagus which form the MIIT. The regional MIIT were correlated to the Hospital Odynophagia Dysphagia Questionnaire (HODQ) scores for clinical dysphagia and severity. Regional MIIT were also compared between achalasia patients (case group) and non-achalasia patients (control group) based on high-resolution manometry (HRM) and barium swallow (BS) diagnosis. Descriptive statistics,

Indexed as

achalasiabariumimpedanceoesophagustransit

Identifiers

PMID39659358
PMCPMC11631163

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.