ArticleKlinische Monatsblatter fur Augenheilkunde2025

Comparison of Ocular Biometry Measurements from Two Swept-Source OCT Devices: Eyestar 900 vs. Anterion.

Julian V Kool van Langenberghe, Petra Schwarzer, Tobias Jahn, Christoph Tappeiner, Dimitrios Kyroudis, Eva Vrbka, David Goldblum

Abstract readComparative Study
In one paragraph

Article in Klinische Monatsblatter fur Augenheilkunde, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Julian V Kool van LangenbergheClinical Affairs & Clinical Operations, Haag-Streit AG, Köniz, Switzerland.
Petra SchwarzerEye Clinic, Pallas Kliniken AG, Olten, Switzerland.
Tobias JahnResearch & Development, Haag-Streit AG, Köniz, Switzerland.
Christoph TappeinerEye Clinic, Pallas Kliniken AG, Olten, Switzerland.ORCID 0000-0001-6907-1112
Dimitrios KyroudisEye Clinic, Pallas Kliniken AG, Olten, Switzerland.
Eva VrbkaEye Clinic, Pallas Kliniken AG, Olten, Switzerland.
David GoldblumEye Clinic, Pallas Kliniken AG, Olten, Switzerland.ORCID 0000-0002-2119-1710

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAdvanced swept-source optical coherence tomography (SS-OCT) devices are the current gold standard for the measurement of ocular biometric and keratometric parameters, which are essential for the calculation and selection of intraocular lenses (IOLs). This study compares the agreement of two SS-OCT devices, the Eyestar 900 (Haag-Streit, Köniz, Switzerland) and the Anterion (Heidelberg Engineering, Heidelberg, Germany). MATERIALS AND

methodsAll patients undergoing cataract surgery or seeking consultation for corneal abnormalities between January 2024 and May 2024 were eligible for inclusion. Both eyes were included in the final analysis.

resultsA sample of 86 eyes from 43 patients was analysed. The mean differences (ES-AN) across all data between the Eyestar 900 (ES) and Anterion (AN) were as follows: anterior chamber depth (ACD) - 0.080 mm (ICC > 0.926), axial length (AL) 0.015 mm (ICC > 0.99), central corneal thickness (CCT) 0.914 µm (ICC > 0.921), corneal curvature along the flat meridian (K1) - 0.024 D (ICC > 0.904), and steep meridian (K2) - 0.210 D (ICC > 0.902), white-to-white corneal diameter (WTW) 0.215 mm (ICC > 0.81). There was excellent agreement for ACD, AL, CCT, K1, K2, and WTW. However, the corneal axis (AX) showed only moderate agreement (ICC > 0.389), with a mean difference of 5.97° and a notable standard deviation of 58.6°.

conclusionsThe Eyestar 900 and Anterion demonstrated substantial agreement for all parameters except for the corneal meridian axis. It may be assumed that the inclusion of eyes with irregular corneal topographies may have contributed to this discrepancy. SUMMARY: Overall, there was a high level of agreement between the Eyestar 900 and Anterion. It is reasonable to assume that the measurement outcomes provided by both devices are interchangeable for the calculation of target refractive outcomes for intraocular lenses, with no clinically relevant differences.

Indexed as

BiometryTomography, Optical CoherenceAgedAged, 80 and overCorneaFemaleHumansLenses, IntraocularMaleMiddle AgedReproducibility of Results

Identifiers

PMID39657761
PMCPMC12020659

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.