Evidence map›Paper›PMID 39650275›Full record

ArticleSovremennye tekhnologii v meditsine2024

Digital Electrocardiographic Complex for Risk Stratification of Paroxysmal Atrial Fibrillation.

A V Frolov, O P Melnikova, A P Vorobiev, T G Vaikhanskaya

Abstract read
In one paragraph

Article in Sovremennye tekhnologii v meditsine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

A V FrolovDSc, Professor, Head of the Laboratory of Medical Information Technologies; Republican Scientific and Practical Centre "Cardiology", Ministry of Health of the Republic of Belarus, 110 R. Luxembourg St., Minsk, 220036, Belarus.
O P MelnikovaSenior Researcher, Laboratory of Medical Information Technologies; Republican Scientific and Practical Centre "Cardiology", Ministry of Health of the Republic of Belarus, 110 R. Luxembourg St., Minsk, 220036, Belarus.
A P VorobievSenior Researcher, Laboratory of Medical Information Technologies; Republican Scientific and Practical Centre "Cardiology", Ministry of Health of the Republic of Belarus, 110 R. Luxembourg St., Minsk, 220036, Belarus.
T G VaikhanskayaMD, PhD, Leading Researcher, Laboratory of Medical Information Technologies; Republican Scientific and Practical Centre "Cardiology", Ministry of Health of the Republic of Belarus, 110 R. Luxembourg St., Minsk, 220036, Belarus.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Materials and Methods: There was developed the hardware and software system "Intecard 8.1" to assess a set of markers for atrial electrical instability by 3-5-minute ECG recordings in sinus rhythm. The markers include P-wave amplitude in lead II <0.1 mV, P-wave duration >120 ms, advanced interatrial block, the area of the biphasic P-wave terminal part <-4 mV·ms, and MVP (morphology-voltage- P-wave duration) score >3 points.The clinical testing of "Intecard 8.1" system was carried out on 120 patients with ischemic heart disease or dilated cardiomyopathy. The patients' average age was 57.9±13.1 years. Results: P-wave detection is a challenging task due to a low signal amplitude, noise, high error probability in atrioventricular block or T-wave and P-wave superposition in case of marked tachycardia. To improve detection, a phase transformation method was used, according to which there was studied its phase component arctg[ Conclusion: The digital electrocardiographic complex "Intecard 8.1" when analyzing 3-5-minute ECG recordings with sinus rhythm enables to identify the patients with high risk or with hidden AF forms. The dynamic assessment of P-wave parameters offers an opportunity to personalize heart rhythm control in this patient cohort.

Indexed as

Atrial FibrillationElectrocardiographyAdultAgedFemaleHumansMaleMiddle AgedRisk AssessmentSoftwareatrial fibrillationdigital electrocardiographyheart rate control“Intecard 8.1”sinus heart rhythm