ArticleJDS communications2024
Comparison of radial immunodiffusion, turbidimetric immunoassay, and Brix refractometry for determining bovine colostrum quality.
Article in JDS communications, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- The Influence of Genotype and Seasonality on the Sow Colostrum Quality and Immunoglobulin G Content.Animals : an open access journal from MDPI · 2025Article
- Effect of frozen storage of bovine colostrum for up to 1 year on concentrations of immunoglobulins and insulin as well as bacterial counts.JDS communications · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Determining the concentration of IgG in colostrum is critical for assessment of colostrum quality. On-farm use of a Brix refractometer to estimate colostrum IgG concentration is widespread, whereas radial immunodiffusion (RID) is the laboratory reference method. Turbidimetric immunoassay (TIA) might offer an alternative method to quantify IgG in colostrum, but the agreement with RID, as well as critical thresholds to determine high-quality colostrum, remain uncertain. The objective of this study was to determine the level of agreement between RID, Brix %, and TIA for evaluation of colostrum quality. Composite colostrum samples (n = 58) from Holstein cows were evaluated using a digital Brix refractometer at the time of collection and stored at -20°C until analysis. The concentration of IgG was determined using RID and TIA. Data were analyzed using Passing-Bablok regression and Bland-Altman plots. Critical thresholds for TIA and Brix measurements to identify colostrum with an IgG concentration ≥50 and ≥100 g/L based on the reference method were determined using logistic regression and receiver operating characteristic curves. Results revealed that both TIA (Kendall's τ = 0.91) and Brix % (τ = 0.78) had a strong correlation with RID. Passing-Bablok regression identified a systematic (6.91 [4.33 to 8.98] g/L) and proportional (0.69 [0.67 to 0.72] g/L) bias between RID and TIA. The optimum thresholds to identify samples with an IgG concentration ≥50 and ≥100 g/L were 40.6 g/L (area under the curve [AUC]: 1.0; sensitivity (Se): 100; specificity [Sp]: 100) and 85.8 g/L (AUC: 0.99; Se: 96.6; Sp: 96.6) for TIA and 18.4% (AUC: 1.0; Se: 100; Sp: 100) and 25.8% (AUC: 0.99; Se: 82.8; Sp: 93.1) for Brix %, respectively. Using the identified thresholds, our results show that both Brix and TIA were highly accurate for identifying high-quality colostrum, but because of a proportional bias, direct comparison of IgG concentration results obtained by RID and TIA are cautioned.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.