Evidence map›Paper›PMID 39649637›Full record

ArticleAnnals of cardiothoracic surgery2024

Electrical graft assessment of machine-perfused hearts donated after circulatory death.

Jorik H Amesz, Mark F A Bierhuizen, Sanne J J Langmuur, Dwight Dumay, Olivier C Manintveld, Yannick J H J Taverne, Natasja M S de Groot

Abstract read
In one paragraph

Article in Annals of cardiothoracic surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Electrophysiological Markers ofTransplant international : official journal of the European Society for Organ Transplantation · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jorik H Amesz *Translational Cardiothoracic Surgery Research Lab, Department of Cardiothoracic Surgery, Erasmus Medical Center, Rotterdam, The Netherlands.
Mark F A Bierhuizen *Translational Cardiothoracic Surgery Research Lab, Department of Cardiothoracic Surgery, Erasmus Medical Center, Rotterdam, The Netherlands.
Sanne J J LangmuurTranslational Cardiothoracic Surgery Research Lab, Department of Cardiothoracic Surgery, Erasmus Medical Center, Rotterdam, The Netherlands.
Dwight DumayDepartment of Clinical Perfusion, Erasmus Medical Center, Rotterdam, The Netherlands.
Olivier C ManintveldErasmus MC Transplant Institute, Erasmus Medical Center, Rotterdam, The Netherlands.
Yannick J H J TaverneTranslational Cardiothoracic Surgery Research Lab, Department of Cardiothoracic Surgery, Erasmus Medical Center, Rotterdam, The Netherlands.
Natasja M S de GrootTranslational Electrophysiology Lab, Department of Cardiology, Erasmus Medical Center, Rotterdam, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Normothermic ex situ heart perfusion (ESHP) has increased the donor pool with hearts donated after circulatory death (DCD), but functional assessment during ESHP using lactate trends is suboptimal. This study presents the clinical use of high-resolution cardiac mapping to assess electrical function of human DCD hearts on ESHP, where low-voltage-areas might be indicative of myocardial injury. Methods: Hearts were procured following circulatory arrest of the donor and restarted on normothermic ESHP. DCD hearts were transported to the recipient hospital and lactate concentrations were regularly measured in the perfusate. High-resolution epicardial mapping of the left (LV) and right ventricle (RV) was performed with a 192-electrode array during normothermic ESHP prior to transplantation. Unipolar potential voltages and slopes, conduction velocity and the amount of low-voltage potentials and conduction block were calculated from these recordings. Results: Electrical mapping was performed on ten DCD hearts transported on ESHP with sequential cardiac transplantation, showing safety and feasibility of the technique. Median potential voltage of the LV and RV was 15.7 mV (14.0-17.4 mV) and 11.3 mV (8.3-11.9 mV) respectively, and low-voltage potentials were minimally present. In comparison, the electrical function of one rejected heart with increasing lactate trend did not differ from the transplanted hearts. Conclusions: High-resolution electrical mapping of DCD hearts on ESHP may serve as novel additional diagnostic tool for assessing graft function, especially in marginal donors.

Indexed as

cardiac mappingdonation after circulatory deathHeart transplantationmachine perfusion

Identifiers

PMID39649637
PMCPMC11618120

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.