ArticleDiagnosis (Berlin, Germany)2025
Screening fasting glucose before the OGTT: near-patient glucometer- or laboratory-based measurement?
Article in Diagnosis (Berlin, Germany), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesThe measurement of fasting glucose is a common practice for lowering the risk of hyperglycemia before an oral glucose tolerance test (OGTT). In this study we analyze advantages and limitations of near-patient measurement of capillary fasting glucose with a portable glucometer or blood sampling and measurement of plasma glucose with laboratory instrumentation.
methodsThe final study population consisted of 241 subjects (mean age: 36 ± 8 years; 97.9 % pregnant women) referred to our local phlebotomy center for an OGTT. Fasting glucose was measured in capillary blood using a near-patient glucometer (glucometer-based strategy) and in plasma with laboratory instrumentation using the hexokinase reference assay (laboratory-based strategy).
resultsThe mean turnaround time from sample collection to obtaining the glucose value was longer with the laboratory-based strategy (32 min 8 vs. 8 s). The imprecision of the glucometer was higher than that of the laboratory assay (3.4 vs. 0.8 %). A negative bias of -3.3 % in fasting glucose was found with the glucometer compared to the laboratory measurement. The diagnostic accuracy, sensitivity and specificity of the glucometer for detecting fasting glucose values ≥7.0 mmol/L were 99.2 , 50.0 and 100.0 % compared to the laboratory assay. The glucometer-based strategy had an incremental cost of 0.17€ per patient compared to the laboratory-based strategy.
conclusionsScreening fasting glucose in capillary blood with a near-patient glucometer instead of measuring fasting plasma glucose with laboratory instrumentation allows faster patient management in the phlebotomy center but is associated with higher imprecision, inaccuracy, costs and avoidable finger pricks.
Indexed as
Identifiers
39648179What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.