Evidence map›Paper›PMID 39645575›Full record

ArticleMedical science monitor : international medical journal of experimental and clinical research2024

Accuracy of 3 Intraoral Scanners in Recording Impressions for Full Arch Dental Implant-Supported Prosthesis: An In Vitro Study.

Saurabh Jain, Mohammed E Sayed, Reem Abdullah A Khawaji, Ghada Ali J Hakami, Eman Hassan M Solan, Manal A Daish, Hossam F Jokhadar, Saad Saleh AlResayes, Majed S Altoman, Abdullah Hasan Alshehri and 5 more

Abstract read
In one paragraph

Article in Medical science monitor : international medical journal of experimental and clinical research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed.

  1. Article
  2. Effect of Die Ditching on the Marginal Fit of CAD/CAM-Fabricated Co-Cr Crowns: An In Vitro Comparative Study.Medical science monitor : international medical journal of experimental and clinical research · 2026
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

15 authors.

Saurabh JainDepartment of Prosthetic Dental Sciences, College of Dentistry, Jazan University, Jazan, Saudi Arabia.ORCID 0000-0002-0071-4068
Mohammed E SayedDepartment of Prosthetic Dental Sciences, College of Dentistry, Jazan University, Jazan, Saudi Arabia.ORCID 0000-0001-8667-8987
Reem Abdullah A KhawajiIntern Clinic, College of Dentistry, Jazan University, Jazan, Saudi Arabia.
Ghada Ali J HakamiIntern Clinic, College of Dentistry, Jazan University, Jazan, Saudi Arabia.
Eman Hassan M SolanIntern Clinic, College of Dentistry, Jazan University, Jazan, Saudi Arabia.
Manal A DaishIntern Clinic, College of Dentistry, Jazan University, Jazan, Saudi Arabia.ORCID 0009-0008-9515-5991
Hossam F JokhadarDepartment of Oral and Maxillofacial Prosthodontics, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia.
Saad Saleh AlResayesDepartment of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Jeddah, Saudi Arabia.ORCID 0000-0002-5569-9133
Majed S AltomanDepartment of Prosthetic Dental Sciences, College of Dentistry, King Khalid University, Abha, Saudi Arabia.ORCID 0000-0002-1061-9574
Abdullah Hasan AlshehriDepartment of Prosthetic Dental Sciences, College of Dentistry, King Khalid University, Abha, Saudi Arabia.ORCID 0000-0003-1097-5218
Saeed M AlqahtaniDepartment of Prosthetic Dental Sciences, College of Dentistry, King Khalid University, Abha, Saudi Arabia.ORCID 0000-0001-9669-2408
Mohammad AlamriDepartment of Restorative Dentistry, College of Dentistry, King Khalid University, Abha, Saudi Arabia.ORCID 0009-0007-5631-7997
Ahid Amer AlshahraniDepartment of Dental Technology, Applied Medical Sciences, King Khalid University, Abha, Saudi Arabia.ORCID 0000-0002-8496-184X
Hind Ziyad Al-NajjarGeneral Dentistry Private Practice, Jeddah, Saudi Arabia.ORCID 0009-0007-0591-3721
Khurshid MattooDepartment of Prosthetic Dental Sciences, College of Dentistry, Jazan University, Jazan, Saudi Arabia.ORCID 0000-0003-1191-437X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND This study used an edentulous mandibular resin model with 6 parallel osteotomy sites and aimed to compare the accuracy (trueness and precision) of 10 digital impressions using 3 intraoral scanners, the 3Shape TRIOS 5, Medit i700, and Primescan, using Medit Link v3.3.2 software. MATERIAL AND METHODS A model simulating a patient's lower jaw was surgically prepared at 6 parallel sites (implant osteotomy), allowing placement of 6 implant analogues. Matrix-Direct transfer abutments were attached to the analogs, and a reference scan was obtained using a CeramilMap 600 extraoral scanner. Three intraoral scanners (3Shape TRIOS 5, Medit i700, and Primescan) made 10 digital impressions of each model. The data obtained were superimposed and compared using software (Medit Link 3.3.2) to evaluate accuracy. Mean values were statistically analyzed using one-way ANOVA and post hoc Tukey test. Differences were considered significant at a P value of less than 0.05. RESULTS The TRIOS 5 intraoral scanner displayed the lowest deviation for precision (37.8±4.53 μm) and trueness (54.9±11 μm), followed by Medit i700 (precision 40.6±4.17 μm, trueness 60.5±10.9 μm), whereas the highest deviation (precision: 49.1±8.31 μm, trueness: 72.3±10.4 μm) was reported when Primescan intraoral scanner was used for recording impressions of full arch implants. When the 3 intraoral scanners were compared, a statistically significant difference was observed in terms of precision (P<0.005) and trueness (P<0.005). CONCLUSIONS TRIOS 5 intraoral scanner displayed the lowest deviation values for precision and trueness (more accurate), followed by Medit i700 and Primescan intraoral scanners. However, deviation values of all scanners were within clinically acceptable limits.

Indexed as

Dental ImplantsDental Impression TechniqueDental Prosthesis, Implant-SupportedComputer-Aided DesignDental ArchHumansMandibleModels, DentalSoftwareDental Implants

Identifiers

PMID39645575
PMCPMC11636004

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.