Evidence map›Paper›PMID 39639197›Full record

ArticleBMC cardiovascular disorders2024

Assessing the repeatability, reliability, and precision of right ventricular outflow tract and mid-pulmonary artery diameters, velocity time integrals, and agreement between site-specific stroke volumes.

Reza Mohseni-Badalabadi, Leila Hosseininejad, Reza Hali, Flora Fallah, Ali Hosseinsabet

Abstract readComparative Study
In one paragraph

Article in BMC cardiovascular disorders, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Reza Mohseni-BadalabadiCardiology Department, Tehran Heart Center, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran.
Leila HosseininejadCardiology Department, Tehran Heart Center, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran.
Reza HaliCardiology Department, Tehran Heart Center, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran.
Flora FallahCardiology Department, Tehran Heart Center, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran.
Ali HosseinsabetCardiology Department, Tehran Heart Center, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran. ali_hosseinsabet@yahoo.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRight ventricular (RV) stroke volume (SV) can be calculated via Doppler echocardiography at multiple sites in the right chambers. However, the agreement between the calculated SVs at these sites is unknown. We aimed to assess the repeatability, reliability, and precision of the distal right ventricular outflow tract diameter (RVOTD), the mid-pulmonary artery diameter (MPAD), the right ventricular outflow tract velocity time integral (VTI), and the mid-pulmonary artery velocity time integral (MPAVTI). Additionally, we evaluated the agreement between RVOTSV and MPASV.

methodsFour observers each evaluated approximately 100 patients (n = 406). Basic measurements were made over three cardiac cycles, and the repeatability, reliability, and precision of the measurements were calculated. The agreement between the two methods was presented as intraclass correlation coefficients.

resultsThe repeatability coefficient ranges for RVOTD, MPAD, RVOTVTI, and MPAVTI were 2-3 mm, 2-4 mm, 2.1-2.8 cm, and 2.4-4.1 cm, respectively. The minimal detectable change ranges for these variables were 2-4 mm, 2-5 mm, 2.2-3.0 cm, and 2.6-4.3 cm, respectively. The respective precision ranges for RVOTD, MPAD, RVOTVTI, and MPAVTI were 2.7-4.7%, 2.4-5.4%, 5.0-7.4%, and 5.4-9.2%. There were significant correlations and agreements between MPASV and RVOTSV, with the Pearson correlation coefficient ranging from 0.63 to 0.89 (P < 0.001). The intraclass correlation coefficient ranged from 0.56 to 0.89 (P < 0.001), although there was a significant bias of 1.9-11.3 mL (P < 0.001).

conclusionsThe RVOTD, MPAD, RVOTVTI, and MPAVTI measurements were repeatable, reliable, and precise. The agreement between RVOTSV and MPASV ranged from fair to excellent, although significant bias, along with a wide limit of agreement, was observed. Consequently, these methods cannot be used interchangeably.

Indexed as

Observer VariationPredictive Value of TestsPulmonary ArteryStroke VolumeVentricular Function, RightAdultAgedBlood Flow VelocityEchocardiography, DopplerFemaleHumansMaleMiddle AgedReproducibility of ResultsTime FactorsAgreementEchocardiographyPrecisionPulmonary arteryReliabilityRepeatabilityRight ventricular outflow tractStroke volume

Identifiers

PMID39639197
PMCPMC11622495

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.