Evidence map›Paper›PMID 39636822›Full record

ArticlePloS one2024

Design analysis and performance enhancement of a 2-element MIMO skin-implantable antenna for IoT-based health monitoring devices.

Anupma Gupta, Mohammad Aljaidi, Shonak Bansal, Rabia Emhamed Al Mamlook, Vipan Kumar, Abeer Aljohani, Saad Aljohani, Manish Kumar Singla

Abstract read
In one paragraph

Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Anupma GuptaDepartment of Interdisciplinary Courses in Engineering, Chitkara University Institute of Engineering and Technology, Chitkara University, Punjab, India.
Mohammad AljaidiDepartment of Computer Science, Faculty of Information Technology, Zarqa University, Zarqa, Jordan.ORCID 0000-0001-9486-3533
Shonak BansalDepartment of Electronics and Communication Engineering, University Institute of Engineering, Chandigarh University, Gharuan, Mohali, India.
Rabia Emhamed Al MamlookDepartment of Mechanical and Industrial Engineering, University of Zawia, Zawia, Libya.
Vipan KumarDepartment of Electronics and Communication Engineering, Sri Sai College of Engineering and Technology, Badhani, Pathankot, India.ORCID 0000-0003-0326-8865
Abeer AljohaniApplied College Taibah University, Madinah, Saudi Arabi.
Saad AljohaniElectrical and Computer Engineering, Western Michigan University, Kalamazoo, Michigan, United States of America.
Manish Kumar SinglaDepartment of Interdisciplinary Courses in Engineering, Chitkara University Institute of Engineering and Technology, Chitkara University, Punjab, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Two two-element slotted patch multiple-input multiple-output (MIMO) antenna with coplanar waveguide (CPW) feed is proposed for deployment in implantable medical devices. Implantable devices are compact and demand high-gain antennae with unidirectional radiation patterns. Regarding compactness, the antenna has a size of 16 × 6×0.25 mm3 for the operating frequency of 2.45 GHz ISM band. Miniaturized antenna geometry is attained using the slots in the radiator and with the coplanar waveguide feed. An element MIMO configuration is used for establishing a reliable communication link. The two radiators maintain a connected ground topology with a minimum edge-to-edge spacing of 7.7 mm. Mutual coupling of -29 dB and operating frequency spectrum of 1300 MHz is attained at the center cut off frequency. Unidirectional power pattern and high gain of 2.3 dB is achieved. The proposed MIMO structure is suitable for mitigating multipath fading effect and realizing higher spectral efficiency in short range communication. The in-tissue measurement results for the scattering parameters and radiation characteristics are done by placing the antenna in a pork loin. Specific absorption rate (SAR) analysis is performed to confirm the user's safety from nearfield EM waves. Antenna has safe SAR value of 0.798 W/kg for 1-g of average tissue for the power of 1-mW. The low envelope correlation coefficient of 0.035 depicts the excellent diversity performance for MIMO operation.

Indexed as

Prostheses and ImplantsWireless TechnologyAnimalsEquipment DesignHumansInternet of ThingsMonitoring, PhysiologicSkinSwine

Identifiers

PMID39636822
PMCPMC11620415

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.