ArticleNanophotonics (Berlin, Germany)2022
Ultrahigh-performance vector magnetic field sensor with wedge-shaped fiber tip based on surface plasmon resonance and magnetic fluid.
Article in Nanophotonics (Berlin, Germany), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Research Progress on Magneto-Refractive Magnetic Field Fiber Sensors.Sensors (Basel, Switzerland) · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A novel fiber-optic vector magnetic field sensor and its sensing quality dependent of fabrication method has been proposed and investigated. The proposed sensor has two surfaces on the tip of a multimode fiber, which is used as the sensing probe. By plating different thickness of gold film on the surfaces, surface plasmon resonance (SPR) can be generated and the signal can be reflected by the surfaces as well. Meanwhile, magnetic fluid (MF) as the magnetic field sensitive material is packed around the sensing probe. The experimental results prove that the response of MF to external magnetic field can be used to sense magnetic field intensity and direction via monitoring the dip wavelength of SPR. The obtained refractive index (RI) sensitivities are 2105 nm/RIU (RI range: 1.332-1.365) and 6692 nm/RIU (RI range: 1.372-1.411), magnetic field intensity sensitivities are 11.67 nm/mT (0°), and -0.47 nm/mT (90°). Besides, the proposed sensing probe is ultracompact and the footprint is extremely small (the length of sensing part is only 615 μm), which is very helpful for magnetic field detection in narrow space and gradient field.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.