Evidence map›Paper›PMID 39634616›Full record

ArticleNanophotonics (Berlin, Germany)2022

Inverse-designed waveguide-based biosensor for high-sensitivity, single-frequency detection of biomolecules.

Haejun Chung, Junjeong Park, Svetlana V Boriskina

Abstract read
In one paragraph

Article in Nanophotonics (Berlin, Germany), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Haejun ChungDepartment of Electrical Engineering, Soongsil University, 06978 Seoul, South Korea.ORCID https://orcid.org/0000-0001-8959-237X
Junjeong ParkDepartment of Electrical Engineering, Soongsil University, 06978 Seoul, South Korea.
Svetlana V BoriskinaDepartment of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Integrated silicon photonic waveguide biosensors have shown great potential for detecting bio-molecules because they enable efficient device functionalization via a well-developed surface chemistry, as well as simple scalable manufacturing, which makes them particularly suitable for low-cost point-of-care diagnostic. The on-chip integrated biosensors can be broadly classified into two types: (i) high-quality factor resonator sensors and (ii) interferometric sensors relying on non-resonant optical elements such as e.g. integrated waveguides. The former type usually requires a broadband or a tunable light source as well as complicated signal post-processing to measure a shift of the resonance frequency, while the latter exhibits a relatively low sensitivity due to the lack of efficient light recycling and phase accumulation mechanism in low quality factor elements. Additionally, high quality factor resonant photonic structures can be very sensitive to the presence of other non-target molecules in the water solution, causing sensor vulnerability to any noise. In this work, we combine a computational "inverse design" technique and a recently introduced high-contrast probe cleavage detection (HCCD) technique to design and optimize waveguide-based biosensors that demonstrate high sensitivity to the target molecule while being less sensitive to noise. The proposed biosensors only require a single frequency (or narrow-band) source and an intensity detector, which greatly simplifies the detection system, making it suitable for point-of-care applications. The optimal integrated sensor design that we demonstrate shows 98.3% transmission for the positive (target detected, probes cleaved) state and 4.9% transmission for the negative (probes are still attached) state at 1550 nm wavelength. The signal intensity contrast (20.06-fold transmission increase) shown in this work is much greater than the shift of the resonance frequency (less than 1% wavelength shift) observed in conventional ring-resonator-based biosensors. The new design may pave the way for realizing a single-frequency highly sensitive and selective optical biosensor system with a small physical footprint and a simple optical readout on a silicon chip.

Indexed as

biosensorinverse designwaveguide

Identifiers

PMID39634616
PMCPMC11501463

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.