Evidence map›Paper›PMID 39628861›Full record

ArticleJournal of clinical orthopaedics and trauma2024

Accuracy of femoral tunnel placement using three different techniques in performing arthroscopic all-inside anterior Cruciate Ligament reconstruction; A randomized study.

Pankaj Rai, Vikas Kulshrestha, Munish Sood, Santhosh Kumar, Mustajib Ali, Soma Kulshrestha

Erratum issuedAbstract read
In one paragraph

Article in Journal of clinical orthopaedics and trauma, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors.

Pankaj RaiClassified Spl Orthopaedics & Head of Department, 5 Air Force Hospital, India.
Vikas KulshresthaDepartment of Orthopaedics, Command Hospital Air Force Station Bangalore, India, 560007.
Munish SoodDepartment of Orthopaedics, INHS Asvini, Mumbai, India, 500004.
Santhosh KumarDepartment of Orthopaedics and Joint Replacement Surgery, AHR&R Delhi Cantt, India.
Mustajib AliGraded Specialist Radiology, 11 Air Force Hospital, India.
Soma KulshresthaSymbiosis Centre for Management Studies, Pune Symbiosis International (Deemed University), Pune, 412115, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: One of the key steps in arthroscopic Anterior Cruciate Ligament Reconstruction (ACLR) is getting the femoral tunnel at the right position to attach the graft. While the correct position has been described as a low and posterior position behind the bifurcate ridge on the medial surface of lateral femoral condyle, to reproducibly achieve it more than one technique is being used by surgeons. There are no randomized studies in literature which have evaluated the efficacy of these in a surgeon's hand. This study attempts to do that. Methods: This randomized study was performed at a military sports injury centre by a single surgical team led by two sports fellowship-trained surgeons. One hundred fifty patients undergoing ACLR surgery were randomized to Anteromedial Portal technique e (AMP)group, Far Anteromedial portal technique (FAMP) group and Outside in drilling (OI) group. We used postoperative three-dimensional Computed Tomogram (3D CT) to study tunnel position (Magnussen method), length and orientation (Basdekis method). Results: 80 % of femoral entry points were in satisfactory position using all three techniques. The ideal position was achieved more often using FAMP & OI technique which was better than AMP, however it was not below level of significance set at P < 0.025 (18, 13 & 5 respectively using FAMP, OI and AMP techniques, p-value 0.08 OI vs AMP & 0.07 AMP vs FAMP). The average femoral tunnel length was longest in OI group 34.72 ± 2.41 mm. The mean FAMP tunnel lengths were significantly smaller than the mean tunnel length of AMP and OI groups. (p-value <0.01 FAMP vs OI and p-value <0.01 FAMP vs AMP). Conclusion: Our study showed that all three techniques achieved acceptable femoral tunnel placement in 80 % cases. However, FAMP and OI technique further improved accuracy of achieving ideal tunnel location and OI technique predictably achieved longer tunnel length preventing risk of lateral blow out while using suspensory fixation.

Indexed as

Anterior cruciate ligament reconstructionAnteromedial portalFar anteromedial portalFemoral tunnelOutside in drilling

Identifiers

PMID39628861
PMCPMC11609244

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.