Evidence map›Paper›PMID 39625122›Full record

ArticleMedical physics2025

CT-augmented digital tomosynthesis image reconstruction in image-guided bronchoscopy interventions.

Fatima Saad, Robert Frysch, Sylvia Saalfeld, Stephan Kellnberger, Jessica Schulz, Rebecca Fahrig, Krish Bhadra, Andreas Nürnberger, Georg Rose

Abstract read
In one paragraph

Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Fatima SaadInstitute for Medical Engineering, Otto-von-Guericke University, Magdeburg, Germany.
Robert FryschInstitute for Medical Engineering, Otto-von-Guericke University, Magdeburg, Germany.
Sylvia SaalfeldResearch Campus STIMULATE, Otto-von-Guericke University, Magdeburg, Germany.
Stephan KellnbergerAdvanced Therapies, Innovation, Siemens Healthcare AG, Forchheim, Germany.
Jessica SchulzResearch Campus STIMULATE, Otto-von-Guericke University, Magdeburg, Germany.
Rebecca FahrigAdvanced Therapies, Innovation, Siemens Healthcare AG, Forchheim, Germany.
Krish BhadraCHI Memorial Rees Skillern Cancer Institute, Chattanooga, Tennessee, USA.
Andreas NürnbergerData and Knowledge Engineering Group, Faculty of Computer Science, Otto-von-Guericke University, Magdeburg, Germany.
Georg RoseInstitute for Medical Engineering, Otto-von-Guericke University, Magdeburg, Germany.

Funding

Bundesministerium für Bildung und Forschung (BMBF) 13GW0473AEuropäischer Sozialfonds (ESF) ZS/2016/08/80646
6 · The paper itself

Abstract

backgroundTransbronchial needle biopsy is crucial for diagnosing lung cancer, yet its efficacy depends on accurately localizing the target lesion and biopsy needle. Digital tomosynthesis (DTS) is considered a promising imaging modality for guiding bronchoscopy procedures due to its low radiation dose and small footprint relative to cone-beam computed tomography (CBCT). However, the image quality of DTS is still not sufficient for an accurate guidance, mainly due to its limited-angle acquisition. PURPOSE: Preoperative computed tomography (CT) scans are often performed prior to bronchoscopy interventions for diagnosis or to plan the procedure. The CT images are of high quality and are characterized by a high spatial resolution compared to intraoperative DTS images. These patient-specific prior CT images and the intraoperative DTS images share a fair amount of anatomical information. The main differences only stem from patient positioning and respiratory motion. When these differences are addressed properly, prior CT images augment intraoperative DTS image reconstruction with strong prior knowledge and potentially enhance DTS image quality.

methodsWe propose in this work a prior-aided DTS image reconstruction technique leveraging prior CT images to improve DTS image quality. This technique is based on a recently published deformable CT-to-DTS image registration algorithm which is customized for bronchoscopy interventions. The main idea is to register a prior CT image to an intermediate DTS image reconstructed using the standard iterative algebraic reconstruction technique (ART), then to re-reconstruct the DTS image using ART and the registered prior CT image as a first estimation.

resultsThe proposed prior-aided reconstruction method was tested on a physical phantom and six patient bronchoscopy datasets. Real DTS data acquired with a pseudo-linear (PL) scan geometry and simulated DTS data generated according to a spherical ellipse (SE) scan geometry were considered. Results evaluated qualitatively by visual inspection and quantitatively by computing Pearson's correlation (PC) with respect to the reference CBCT images suggest significant improvements in image quality using the prior-aided DTS reconstruction compared to the standard zero-initialized ART reconstruction. PC coefficients of the six patient datasets were on average

conclusionsWhile the initial estimation in iterative reconstruction algorithms is often overlooked, we proved that initial estimation is of critical importance in DTS image reconstruction and we have demonstrated the profound advantages of integrating prior CT images in intraoperative DTS image reconstruction. CT-augmented DTS offers a viable alternative to CBCT in guiding bronchoscopy interventions at a fraction of the radiation dose. Further clinical studies are needed to validate improved diagnostic yield.

Indexed as

BronchoscopyImage Processing, Computer-AssistedSurgery, Computer-AssistedTomography, X-Ray ComputedHumansPhantoms, Imagingcomputed tomographydigital tomosynthesisimage reconstructioninterventional bronchoscopyprior‐aided reconstructiontransbronchial needle biopsy

Identifiers

PMID39625122
PMCPMC11880646

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.