Evidence map›Paper›PMID 39625106›Full record

ArticleJournal of applied clinical medical physics2025

Low dose threshold for measuring cardiac functional metrics using four-dimensional CT with deep learning.

Pengwei Wu, Kyle Kim, Lauren Severance, Elliot McVeigh, Jed Douglas Pack

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Review
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Pengwei WuGE Healthcare Technology & Innovation Center, Niskayuna, New York, USA.
Kyle KimDepartment of Bioengineering, Medicine, Radiology at University of California San Diego, La Jolla, California, USA.
Lauren SeveranceDepartment of Bioengineering, Medicine, Radiology at University of California San Diego, La Jolla, California, USA.
Elliot McVeighDepartment of Bioengineering, Medicine, Radiology at University of California San Diego, La Jolla, California, USA.
Jed Douglas PackGE Healthcare Technology & Innovation Center, Niskayuna, New York, USA.

Funding

True 4DCT for Quantifying LV Dyssynchrony and Function for Targeting LV Lead Location in CRTR01HL144678 · NHLBI · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI MCVEIGH, ELLIOT R · 2019 to 2022
$3.3M
NHLBI NIH HHS R01 HL144678NHLBI NIH HHS R01 HL14678
6 · The paper itself

Abstract

backgroundFour-dimensional CT is increasingly used for functional cardiac imaging, including prognosis for conditions such as heart failure and post myocardial infarction. However, radiation dose from an acquisition spanning the full cardiac cycle remains a concern. This work investigates the possibility of dose reduction in 4DCT using deep learning (DL)-based segmentation techniques as an objective observer.

methodsA 3D residual U-Net was developed for segmentation of left ventricle (LV) myocardium and blood pool. Two networks were trained: Standard DL (trained with only standard-dose [SD] data) and Noise-Robust DL (additionally trained with low-dose data). The primary goal of the proposed DL methods is to serve as an unbiased and consistent observer for functional analysis performance. Functional cardiac metrics including ejection fraction (EF), global longitudinal strain (GLS), circumferential strain (CS), and wall thickness (WT), were measured for an external test set of 250 Cardiac CT volumes reconstructed at five different dose levels.

resultsFunctional metrics obtained from DL segmentations of standard dose images matched well with those from expert manual analysis. Utilizing Standard-DL, absolute difference between DL-derived metrics obtained with standard dose data and 100 mA (corresponding to ∼76 ± 13% dose reduction) data was less than 0.8 ± 1.0% for EF, GLS, and CS, and 5.6 ± 6.7% for Average WT. Performance variation of Noise-Robust DL remained acceptable at even 50 mA.

conclusionWe demonstrate that on average radiation dose can be reduced by a factor of 5 while introducing minimal changes to global functional metrics (especially EF, GLS, and CS). The robustness to reduced image quality can be further boosted by using emulated low-dose data in the DL training set.

Indexed as

Deep LearningFour-Dimensional Computed TomographyHeartImage Processing, Computer-AssistedAlgorithmsHumansRadiation DosageCardiac CTdeep Learningfunctional Analysislow‐dose CT

Identifiers

PMID39625106
PMCPMC11799918

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.