Evidence map›Paper›PMID 39624261›Full record

ArticleFrontiers in robotics and AI2024

On the feasibility of a robotic probe manipulator for echocardiography in the prone position.

Muhammad Wildan Gifari, Tomoko Machino-Ohtsuka, Takeshi Machino, Modar Hassan, Kenji Suzuki

Abstract read
In one paragraph

Article in Frontiers in robotics and AI, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Muhammad Wildan GifariSchool of Integrative and Global Major, University of Tsukuba, Tsukuba, Japan.
Tomoko Machino-OhtsukaDepartment of Cardiology, Institute of Medicine, University of Tsukuba, Tsukuba, Japan.
Takeshi MachinoDepartment of Cardiology, Institute of Medicine, University of Tsukuba, Tsukuba, Japan.
Modar HassanInstitute of Systems and Information Engineering, University of Tsukuba, Tsukuba, Japan.
Kenji SuzukiInstitute of Systems and Information Engineering, University of Tsukuba, Tsukuba, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Robotic probe manipulator for echocardography (echo) can potentially reduce cardiac radiologists' physical burden. Echo procedure with industrial robots has wide Range of Motion (RoM) but poses safety risks because the robot may clamp the patient against the bed. Conversely, a soft robotic manipulator for echo has safe contact force but suffers from a limited RoM. Due to COVID-19, cardiac radiologists explored performing echo in the prone-positioned patients, which yielded good-quality images but was difficult to perform manually. From robot design perspective, prone position allows safer robot without clamping issue because all actuators are under the patient with minimal RoM to reach the cardiac windows. In this work, we propose a robotic probe manipulator for echo in the prone position employing a combination of a delta 3D printer and a soft end-effector and investigate its feasibility in a clinical setting. We implemented the robot as a scanner type device in which the probe manipulator scans from under a bed with an opening around the chest area. The doctor controls the robot with a joystick and a keypad while looking at a camera view of the chest area and the ultrasound display as feedback. For the experiments, three doctors and three medical students scanned the parasternal window of the same healthy subject with the robot and then manually. Two expert cardiologists evaluated the captured ultrasound images. All medical personnel could obtain all the required views with the robot, but the scanning time was considerably longer than the manual one. The ultrasound image quality scores of the doctors' group remained constant between manual and robotic scans. However, the image scores of the robotic scan were lower in the students' group. In summary, this work verified the ability to obtain clinically sufficient images in echocardiography in the prone position by expert medical doctors using the proposed robotic probe manipulator. Our robot can be further developed with semi automatic procedure to serve as a platform for safe and ergonomic echocardiography.

Indexed as

echocardiographymedical robotsprone positionrobotic ultrasoundsoft robots

Identifiers

PMID39624261
PMCPMC11610407

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked