Evidence map›Paper›PMID 39624071›Full record

ArticleApplied bionics and biomechanics2024

Motion Accuracy of Pneumatic Stepper Motor-Driven Robotic System Developed for MRI-Guided High-Intensity Focused Ultrasound Treatment of Prostate Disease.

Hyunkwan Seo, Sung Kwan Hwang, Hee-Won Kim, Kyu Chan Lee

Abstract read
In one paragraph

Article in Applied bionics and biomechanics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Hyunkwan SeoGachon Biomedical Convergence Institute, Gachon University Gil Medical Center, Incheon, Republic of Korea.ORCID https://orcid.org/0009-0009-6443-934X
Sung Kwan HwangMedrobotics, Seongnam-si, Gyeonggi-do, Republic of Korea.ORCID https://orcid.org/0009-0009-9607-9932
Hee-Won KimCoretech Co., Ltd., Seongnam-si, Gyeonggi-do, Republic of Korea.ORCID https://orcid.org/0009-0000-2292-4923
Kyu Chan LeeDepartment of Radiation Oncology, Gil Medical Center, Gachon University College of Medicine, Incheon, Republic of Korea.ORCID https://orcid.org/0000-0002-6295-3996

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The latest advancement in high-intensity focused ultrasound (HIFU) treatment technology integrates magnetic resonance imaging (MRI) guidance for precise treatment of prostate disease. As conventional electromagnetic motors are not applicable for utilization within MRI scanners, we have developed a prototype robotic system driven by pneumatic stepper motors to control the movement of the HIFU transducer within an intrarectal probe during MRI-guided HIFU treatment procedures. These pneumatic stepper motors were constructed entirely from MRI-compatible plastic materials. Assessment of the robotic system's MRI compatibility was conducted utilizing a 3.0T MRI scanner, revealing no discernible MRI image distortion with a minor decrease in the signal-to-noise ratio (2.8%) during the motor operation. The robotic system enabled the transducer to move inside the probe with two degrees of freedom, allowing both linear and rotational motion. The positional accuracy of the transducer movement was assessed, yielding ±0.20 and ±0.22 mm accuracies in the forward and backward linear movements, respectively, and ±0.79° and ±0.74° accuracies in the clockwise and counterclockwise rotational motions, respectively. Emulation of authentic HIFU procedures involved creating a two-dimensional array of thermal lesions in a tissue-mimicking phantom, achieving positional accuracy within ±1 mm for the generated HIFU focal spots. The prototype robotic system incorporating pneumatic stepper motors fabricated entirely from MRI-compatible plastic materials has demonstrated the requisite positional accuracy necessary for effective HIFU treatment of prostate disease, indicating substantial promise for future clinical application.

Identifiers

PMID39624071
PMCPMC11611392

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.