Evidence map›Paper›PMID 39622862›Full record

ArticleScientific reports2024

Effective optimal control of a wind turbine system with hybrid energy storage and hybrid MPPT approach.

D Rekioua, N Mezzai, Z Mokrani, A Oubelaid, K Kakouche, P O Logerais, Muhannad Alshareef, Mohit Bajaj, Milkias Berhanu Tuka, Sherif S M Ghoneim

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

D RekiouaUniversité de Bejaia, Faculté de Technologie, Laboratoire de Technologie Industrielle et de l'Information, Bejaia, 06000, Algeria.
N MezzaiUniversité de Bejaia, Faculté de Technologie, Laboratoire de Technologie Industrielle et de l'Information, Bejaia, 06000, Algeria.
Z MokraniUniversité de Bejaia, Faculté de Technologie, Laboratoire de Technologie Industrielle et de l'Information, Bejaia, 06000, Algeria.
A OubelaidUniversité de Bejaia, Faculté de Technologie, Laboratoire de Technologie Industrielle et de l'Information, Bejaia, 06000, Algeria.
K KakoucheUniversité de Bejaia, Faculté de Technologie, Laboratoire de Technologie Industrielle et de l'Information, Bejaia, 06000, Algeria.
P O LogeraisUniv Paris Est Créteil, CERTES, IUT de Sénart-Fontainebleau, Lieusaint, F-77567, France.
Muhannad AlshareefDepartment of Electrical Engineering, College of Engineering and Computing in Al-Qunfudhah, Umm al-Qura University, Mecca, Saudi Arabia.
Mohit BajajDepartment of Electrical Engineering, Graphic Era (Deemed to be University), Dehradun, 248002, India. thebestbajaj@gmail.com.
Milkias Berhanu TukaDepartment of Electrical and Computer Engineering, College of Engineering, Sustainable Energy Center of Excellence, Addis Ababa Science and Technology University, Addis Ababa, Ethiopia. milkias.berhanu@aastu.edu.et.
Sherif S M GhoneimDepartment of Electrical Engineering, College of Engineering, Taif University, Taif, 21944, Saudi Arabia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This research paper discusses a wind turbine system and its integration in remote locations using a hybrid power optimization approach and a hybrid storage system. Wind turbine systems' optimization controllers operate MPPT strategies efficiently, optimizing the system's overall performance. The proposed approach is HTb(P&O/FLC), which combines the P&O and FLC methods. This innovative hybrid MPPT strategy takes advantage of the two methods. It maximizes the wind power thus minimizing stress on the storage system. For storage, batteries are important in isolated renewable energy systems due the interminent renewable sources. Unfortunately, they have some drawbacks as lower energy density, and limited charge-discharge. Besides, supercapacitors (SCs) have advantages as quick charging and discharging and long cycle life and some drawbacks as lower energy density and specific voltage requirements. This paper proposes a hybrid storage system combining batteries and SCs. To manage the two storage technologies, an effective algorithm isproposed focusing on managing their storage systems. The findings indicate that the proposed strategy effectively maintains the state of charge (SOC) of both the batteries and SCs in the intended limits. Simulation under MATLAB and Real-time with RT-LAB were carried out to validate the proposed control approach for the wind turbine system.

Indexed as

BatteriesHybrid energy storageHybrid MPPTOptimal controlPower management controlSupercapacitorWind turbine

Identifiers

PMID39622862
PMCPMC11612302

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.