ArticleOpen heart2024
Diagnostic performance of a point-of-care high-sensitivity cardiac troponin I assay among Chinese patients with chest pain.
Article in Open heart, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Analytical and Clinical Performance of High-Sensitivity Cardiac Troponin Point-of-Care Assays as an Aid in the Diagnosis of Myocardial Infarction: A Narrative Review.Emergency medicine international · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundA novel handheld point-of-care high-sensitivity cardiac troponin I analyser has recently been introduced to the market. Evaluating its diagnostic performance against laboratory standards is imperative, given the variations in cardiac troponin levels across populations. This study compared the diagnostic performance between the point-of-care high-sensitivity cardiac troponin I assay (Siemens Healthineers Atellica VTLi) and a laboratory high-sensitivity cardiac troponin I assay (Abbott ARCHITECT STAT High Sensitive Troponin-I) performed using blood samples from various populations (overall, male, female, younger and older) of Chinese patients with chest pain.
methodsThis cross-sectional study included 585 consecutive Chinese patients (age ≥18 year) who presented to an emergency department with chest pain (lasting >5 min) and were managed following the chest pain protocol between 1 August 2023 and 12 June 2024. For both assays, blood samples were collected at two time points (0 hour (initial) and 3 hour (subsequent)). The primary outcome was the diagnostic performance of the two assays, evaluated with their 99th percentile upper reference limits used as the cut-off values for diagnosing myocardial infarction. The gold standard for comparison was the final diagnoses made by attending physicians.
resultsThe point-of-care and laboratory assays exhibited equivalent sensitivity and negative predictive values (both 100%) for blood samples collected at both time points. However, the point-of-care assay outperformed the laboratory assay in terms of specificity (initial: 90.5% to 96.3% vs 79.8% to 94.7%; subsequent: 87.8% to 94.8% vs 77.7% to 92.4%) and positive predictive value (initial: 24.4% to 30.8% vs 11.6% to 23.5%; subsequent: 12.5% to 25.0% vs 5.9% to 18.8%), particularly in older patients.
conclusionThe point-of-care assay is recommended for rapid clinical decision-making. Future studies should explore the effects of its integration into clinical practice and the feasibility of using sex-race-age-specific 99th percentile upper reference limits to enhance its diagnostic performance.