ArticleSkin pharmacology and physiology2024
In vivo Study to Evaluate an Intelligent Algorithm for Time Efficient Detection of Malignant Melanoma Using Dermatofluoroscopy.
Article in Skin pharmacology and physiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- From Fundamentals of Laser-Induced Breakdown Spectroscopy to Recent Advancements in Cancer Detection and Calcified Tissues Analysis: An Overview (2015-2025).Molecules (Basel, Switzerland) · 2025Review
- In vivo Study to Evaluate an Intelligent Algorithm for Time Efficient Detection of Malignant Melanoma Using Dermatofluoroscopy.Skin pharmacology and physiology · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionDermatofluoroscopy is an optical noninvasive method of melanoma/nevus differentiation that has shown 89% sensitivity and 45% specificity in clinical trials, but long measurement duration hinders clinical use. An intelligent algorithm was developed to shorten the measurement time without compromising its diagnostic accuracy. It uses dermoscopic images of the skin lesions to be measured to select measurement points based on the assessment of color values.
methods27 patients with a total of 29 lesions suggestive of cutaneous melanoma were included in a clinical study and measured with both methods, conventional dermatofluoroscopy and the newly developed intelligent algorithm. The results were compared to the independent findings of two histopathologists to evaluate diagnostic accuracy and time saved.
resultsThere was a median reduction of measurement points from 265 to 158 (40%). Meanwhile, the intelligent algorithm showed a higher diagnostic accuracy than conventional dermatofluoroscopy (area under the curve of 72% vs. 63%).
conclusionThe intelligent algorithm did not perform inferior to the conventional method while saving 40% of time. However, measurement times remain long compared to other noninvasive methods of diagnosing malignant melanoma. Further studies are needed to evaluate clinical suitability.
introductionDermatofluoroscopy is an optical noninvasive method of melanoma/nevus differentiation that has shown 89% sensitivity and 45% specificity in clinical trials, but long measurement duration hinders clinical use. An intelligent algorithm was developed to shorten the measurement time without compromising its diagnostic accuracy. It uses dermoscopic images of the skin lesions to be measured to select measurement points based on the assessment of color values.
methods27 patients with a total of 29 lesions suggestive of cutaneous melanoma were included in a clinical study and measured with both methods, conventional dermatofluoroscopy and the newly developed intelligent algorithm. The results were compared to the independent findings of two histopathologists to evaluate diagnostic accuracy and time saved.
resultsThere was a median reduction of measurement points from 265 to 158 (40%). Meanwhile, the intelligent algorithm showed a higher diagnostic accuracy than conventional dermatofluoroscopy (area under the curve of 72% vs. 63%).
conclusionThe intelligent algorithm did not perform inferior to the conventional method while saving 40% of time. However, measurement times remain long compared to other noninvasive methods of diagnosing malignant melanoma. Further studies are needed to evaluate clinical suitability.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.